Télécharger Imprimer la page

Acument TORX WCG Serie Instructions page 4

Conversion au gaz propane

Publicité

Les langues disponibles

Les langues disponibles

The gas pressure regulator has 2 settings that are stamped on
either side of the cap. Turn the cap and reinstall into regulator
with the stamp "LP" visible from the outside of the regulator.
Style 2: The cap does not have a slot and requires a wrench to
be removed.
Remove the access cap by using a wrench, turning the access
cap counterclockwise.
Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "NAT" or "LP" position. Turn over the spring
retainer so the "LP" is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
E
D
A. Access cap
B. Gasket
C.Gas pressure regulator
4. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Propane Gas:
Minimum pressure 10" (25.4 cm) W.C.P.
Supply pressure 14" (35.5 cm) W.C.P.
Gas Supply Pressure Testing
Line pressure testing above 1/2 psi (3.5 kPa) gauge
(14" [35.5 cm] WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa) gauge
(14" [35.5 cm] WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
5. If the burner grates are installed, remove them.
Use the following charts to match the correct gas orifice
spud with the burner location and model being converted.
4
A
B
C
D. LP position
E. NAT position
Propane Gas Orifice Spud Chart for Kit W10676661
Burner
Color
Stamp (A)
Rating
5,000 BTU
Green
66
7,000 BTU
White
75
8,000 BTU
Orange
79
11,000 BTU
Red
97
13,000 BTU
Yellow
108
16,000 BTU
Pink
115
12,000 BTU
Inner
Brown
85
Outer
Brown
48
Burner Models for Kit W10676661
Model No.
Left
Left
Front
Rear
WCG51US0D
66
108
MGC7430D
Green
Yellow
ICS500DS00
WCG75US0D
66
115
MGC9530D
Green
Pink
WCG97US0D
75
79
KCGS350E
White
Orange
ICS655DS00
WCG51US6D
75
75
MGC7536D
White
White
WCG97US6D
75
75
MGC9536D
White
White
KCGS356E
Propane Gas Orifice Spud Chart for Kit W10676662
Burner
Color
Stamp (A)
Rating
5,000 BTU
White
66
6,000 BTU
Green
70
9,100 BTU
Black
89
11,000 BTU
Orange
97
13,000 BTU
Inner
Blue
45
Outer
Brown
97
14,000 BTU
Inner
Blue
45
Outer
Yellow
101
16,000 BTU
Inner
Blue
45
Outer
Red
105
9,000 BTU
Inner
Pink
40
Outer
Pink
80
Size
0.66 mm
0.75 mm
0.79 mm
0.97 mm
A
1.08 mm
1.15 mm
0.85 mm
0.48 mm
A. Size stamp
Center
Center
Right
Right
Inner
Outer
Rear
Front
N/A
N/A
97
Red
White
N/A
N/A
97
Red
White
85
48
66
Brown
Brown
Green
White
108
N/A
66
Yellow
Green
85
48
66
Brown
Brown
Green
Size
0.66 mm
0.70 mm
0.89 mm
0.97 mm
0.45 mm
0.97 mm
0.45 mm
1.01 mm
0.45 mm
1.05 mm
0.40 mm
A. Size stamp
0.80 mm
75
75
75
97
Red
97
Red
A

Publicité

loading

Ce manuel est également adapté pour:

Torx mgc serieTorx kcgs serieTorx ics5/6 serie