InStaLL ranGe Hood (ducted VerSIon)
maKe eLectrIcaL connectIon
WarnInG
electrical Shock Hazard
disconnect power before servicing.
replace all parts and panels before
operating.
failure to do so can result in death or
electrical shock.
1. Disconnect power.
G
C
D
A
B
2. Use UL listed wire connectors and connect
white wires (A) together.
3. Use UL listed wire connectors and connect
black wires (B) together.
4. Connect green (or bare) ground wire from
power supply to green ground screw in
terminal box and securely tighten.
5. Install terminal box cover.
6. Reconnect power
A.White wires
B. Black wires
C. UL listed wire connector
E
D. Green (or bare) ground
wire
E. Home power supply cable
F. UL listed or CSA approved
½" strain relief
G. Green ground screw
F
WarnInG
fire Hazard
electrically ground the blower. use
copper wire.
connect ground wire to green ground
screw in terminal box. failure to do so
can result in death, fire or electrical
shock.
complete Installation
1. Replace grease filter if removed. See the
"Range Hood Care" section.
2. Check the operation of the range hood fan and
light. See "Range Hood Use" section. If range
hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse
has blown. Disconnect power and check wiring
connections.
note
to get the most efficient use from your
new range hood, read the range Hood
use" section.