PREPARING THE OPENING
17-1MAINTAIN
THE FOLLOWING
MINIMUM
CLEARANCE
DIMENSIONS
13" MAX. Depth of unprotected
overhead
cabinets
\
6" MIN. clearance
from
cutout to side wall on
the right of the unit
30" MIN. clearance
from
18" MIN. height
_--
from countertop
countertop
to unprotected
/
overhead
surface
to nearest cabinet
on either side of
unit
3-3/4" MIN. clearance
from cutout to side wall
on the left of the unit
NOTE: All gas cooktop
models
require
7/16"
free area below
cooktop
height
to
combustible
material.
OVERALL
COOKTOP
DIMENSIONS
21" (21-1/4" Max. for
_,.,_
odels)
3"
CUTOUT
DIMENSIONS
OF
COUNTERTOP
To ensure
accuracy,
it is best to make
a template
when
cutting
the opening
in the counter.
_9-1/8"
width
33-7/8" J
_'---_
"_--_.._:_
length
_
16-15/16"
2-1/4" Min. Between'n ''_
°f_.cut__
I
cutout and the wall
_"-_
_
II
behind the cooktop
//
i 1 lm
"
2_1/2- Min. from
front edge of
cutout and front
edge of countertop
cut
RECOMMENDED
GAS SUPPLY
LOCATION
FROM BACKWALL
Recommended
gas supply
location
1" Min. From Backwall
t
From Cutout
Center Line
MAKE SURE WALL
COVERINGS,
COU NTERTOP
AND CABINETS
AROUND
COOKTOP CAN WITHSTAND
HEAT (UP TO 200°F)
GENERATED
BY COOKTOP
Wall covering,
cabinets and
countertop
must withstand
heat up to
200°F