Télécharger Imprimer la page

Victron energy Phoenix Inverter Compact C12/1600 230V Manuel page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
8. TECHNICAL DATA
Phoenix Inverter
INVERTER
Input voltage range (V DC)
Output
Cont. output power at 25°C (VA) (3)
Cont. output power at 25°C (W)
Cont. output power at 40°C (W)
Cont. output power at 65°C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
Zero load power in search mode (W)
GENERAL
Programmable relay (4)
Protection (2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230 V AC-connection
Weight (kg)
Dimensions (hxwxd in mm)
STANDARDS
Safety
Emission / Immunity
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) Programmable relay which can be set for general alarm, DC undervoltage or genset start signal function
12 Volt
24 Volt
Operating temp. range: -40 to +65°C (fan assisted
cooling) Humidity (non condensing): max 95%
Material & Colour: aluminium (blue RAL 5012)
EN 55014-1, EN 55014-2, EN 61000-3-3
C 12/1200
C 24/1200
9,5 – 17V
19 – 33V
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
1200
1000
900
600
2400
92 / 94
8 / 10
2 / 3
yes
a - g
Protection category: IP 21
Battery cables of 1.5 meter
G-ST18i connector
10
375x214x110
EN 60335-1, EN 60335-2-29
C 12/1600
C 24/1600
1600
1300
1200
800
3000
92 / 94
8 / 10
2 / 3
15

Publicité