7.3
fl ame characteristics
It is important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration
provided. If any fl ames appear abnormal, call a service person.
TDI3 / TDI3E
7.4
optional wall switch
WARNING
!
•
Do not connect either the wall switch, thermostat or gas valve directly to 110 volt electricity.
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:
WIRE SIZE
14 gauge (1.8mm)
16 gauge (1.5mm)
18 gauge (1.2mm)
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.
TDIG3
MAX. LENGTH
100 feet (30.5m)
60 feet (18.3m)
40 feet (12.2m)
adjustments
TDIX3
ADD IMAGE
HERE