Télécharger Imprimer la page

Timberwolf Gas Insert Serie Manuel D'installation page 10

Publicité

Les langues disponibles

Les langues disponibles

general information
EN
1.5
dimensions
3"
2 PLS
Ref.
A
B
* Dimension with optional blower kit installed.
1.6
minimum clearance to combustibles
This appliance must be recessed into a vented non-combustible wood-burning appliance (prefabricated or masonry)
only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 21 1/2" (54.6cm)
The minimum allowable chimney fl ue size is 6" (152mm) round.
*Add 4" (102mm) for optional blower.
The minimum distance from the bottom of a combustible mantel projecting 3" (76mm) maximum from the wall to
the top of the appliance is 12" (30.4cm) (see "minimum mantel clearances" section).
note:
A non-combustible hearth must protrude a minimum of 12" (30.5cm) from the appliance.
A combustible hearth may be used if the appliance is raised 4" (102mm) above the hearth or if a Wolf Steel
raiser box is installed.
10
W415-2883 / A / 07.13.20
front view
SAFETY BARRIER
23 5
"
8
601mm
17 7
"
8
454mm
365mm
28 5
"
8
728mm
top view
TDI3
TDI3E
13 7/16" [341mm]
7 1/2" [190mm]
WIDTH 29" (73.7cm)
20 15
"
16
531mm
A
*
18 5
14 3
"
15 3
"
"
16
8
16
465mm
386mm
TDIG3
13 13/16" [376mm]
DEPTH * 14 3/8" (36.6cm)
right side view
B
4 3
" 106mm
16
back view
TDIX3
6 7/8" [175mm]

Publicité

loading

Ce manuel est également adapté pour:

Tdig3Tdi3nTdi3neTdig3nTdix3nTdi3p ... Afficher tout