5. If you want to connect more units, simply repeat step 4. Up to 24 alarms can be
interconnected this way. To ensure that all alarms enter the same interlinked
network, make sure you only work with 2 units at a time—one unit enters the
pairing mode and the other unit enters the searching mode.
6. Test the alarms according to the steps in the section "Alarm Test".
04
NOTES
1. The alarm will enter the searching mode or the pairing mode for 60 seconds with the
LED flashing red. After 60 seconds, repeat step 2 to connect the alarms. If needed,
press the pairing button once while the alarm is in the searching mode or the pairing
mode, and the LED will stop flashing red and the alarm will quit the pairing mode to
enter normal status.
2. Test all wireless alarms to ensure they are interconnected before installation.
3. A maximum of 24 wireless alarms can be interconnected on the same network.
4. The model can only be interconnected with other X-Sense Link
alarms.
Hold down
the test/silence button
wireless interlinked
+
08
How to Disconnect
Press the pairing button 4 times; the alarm will beep once. Then, hold down the pairing
button until the unit beeps once more to disconnect. After disconnecting, it can be
reconnected to the same network, or added to a new network.
NOTE: The X-Sense Link
wireless interlinked alarms in one multi-pack have already been
+
interconnected. To create a new network, you will first need to disconnect each alarm
individually in this multi-pack to avoid having them all join the same network.
Alarm Mode
X-Sense Link
+
wireless interlinked alarms can be interconnected such that any unit that
senses danger will cause all other units in the interconnected network to alarm.
1. If the Initiating Unit Is Triggered by Smoke/Heat:
When one smoke/heat alarm is triggered in the interconnected network, the unit will
beep 3 times, paired with the LED that flashes red every 4 seconds. Any other
interconnected units will follow suit—they will beep 3 times every 4 seconds, paired
with the LED flashing red and green in succession.
2. If the Initiating Unit Is Triggered by CO:
When one CO alarm is triggered in the interconnected network, the unit will beep 4
times every 5.8 seconds, paired with the LED flashing red. Any other interconnected
units in the network will follow suit—they will beep 4 times every 5.8 seconds, paired
with the LED that flashes red 4 times first, followed by the LED that flashes green once
with every beep. When the CO concentration level drops below the alarm threshold,
the alarm will cease.
09