The LED flashes green
once every second for
5 seconds.
Test
Test a single
The LED flashes red 4
Mode
unit.
times every 4 seconds.
Test all
The LED flashes red
interconnected
rapidly.
units.
The LED flashes red
and green sequentially.
Silence Mode
The LED flashes red
once every 5 seconds.
Low Battery
The LED flashes red
once every 60 seconds.
None.
Alarm cancellation:
When the
temperature drops
below the alarm
threshold, the
alarm signal will
stop. Then, the
alarm goes back to
the standby mode.
3 beeps every
Press the
4 seconds.
test/silence
button.
Continuous
Initiating unit.
beeping until
Hold down the
you release
test/silence button
the
on one unit in the
test/silence
network.
button.
Other
interconnected
alarms in the
network.
None.
After 9 minutes,
the unit will exit
silence mode.
1 beep every
Replace the unit
60 seconds.
immediately.
18
Malfunction
The LED flashes red
twice every 60 seconds.
Technical Specifications
Power Supply
10-year sealed lithium battery (non-replaceable)
Sensor Type
NTC thermistor
Heat Sensitivity
129–149°F (54–65°C)
Safety Standard
BS 5446-2:2003
Operating Temperature
40–100°F (4.4–37.8°C)
Operating Relative Humidity
≤ 85% RH (non-condensing)
Alarm Loudness
≥ 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration
About 9 minutes
Operating Frequency
868 MHz
Maximum Number of
24 wireless units (only compatible with X-Sense
Interconnected Units
Link
+
Transmission Range
Over 820 ft (250 m) in open air
NOTES
1. Battery life is calculated on the current ratings in the standby mode with weekly
testings. If its operation mode changes to an alarming condition, the battery life will be
decreased accordingly.
2. The heat alarm functions between 40 and 100°F (4.4 and 37.8°C). Prolonged exposure to
temperatures outside of this range can reduce battery life and affect accuracy. We do not
recommend operating the device outside of this range.