Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases.
Do not vent gases into the atmosphere.
Refrigerant type:
R32
GWP
(1)
value:
675
GWP = Global Warming Potential
(1)
1 Please fill in with indelible ink,
 A the factory refrigerant charge of the product,
 B the additional refrigerant amount charged in the field and
 A + B the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the service
cover).
Contains fluorinated greenhouse gases
R32
1
=
GWP: 675
2
=
2
1
+
1
2
=
GWP × kg
=
1000
a Factory refrigerant charge: see unit name plate
b Additional refrigerant amount charged
c Total refrigerant charge
d Greenhouse gas emissions of the total refrigerant charge expressed as tonnes CO
e GWP = Global warming potential
NOTICE
In Europe, the greenhouse gas emissions of the total refrigerant charge in the system
(expressed as tonnes CO
Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in kg] / 1000
2 Fix the label on the inside of the outdoor unit. There is a dedicated place for it on the wiring diagram label.
IMPORTANT
kg
kg
kg
tCO
eq
2
-equivalent) is used to determine the maintenance intervals.
2
1-8
-equivalent