Wiring Remote Temperature Sensor
The EcoNet Smart Thermostat is optimized to work with the Aprilaire 8051 Temperature Sensor (10K thermistor).
Use the S1 and S2 terminals on the wall plate terminal block. Only one remote temperature sensor can
be supported.
Basic Settings
80
68
80
Set Point Deadband
2º F
Resume Schedule
Away
75
71
75
Temperature Offset
0.0º F
Relative Humidity Offset
0.0 %
Room Sensor Selection
Internal
Home
Away
Proximity Sensing?
No
Smooth Arrival Enabled?
No
65
72
OFF
BACK
The following table shows the correct resistance at various ambient temperatures without the sensor wires attached to
the thermostat.
Temperature (°F)
30
40
50
60
70
80
90
100
> Return to Table of Contents
Go to Menu > Settings > Basic > Room Sensor Selection. You can choose
Zone 3
to have the system function based on the temperatures measured by the internal
sensor of the thermostat, the remote sensor or the average between the two
sensors.
44%
44%
47%
Dining Room
MORE
Resistance (kΩ)
34.6
26.1
19.9
15.3
11.9
9.4
7 .4
5.9
EcoNet
Smart Thermostat User Guide
®
27