Télécharger Imprimer la page

Chicago Pneumatic CP 0112 Manuel D'instructions page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
CP 0112, CP 0112 S, CP 0112 EX
Wide bladed chisel
WARNING
Vibration hazard
Using inserted tools that do not fulfil the criterias
mentioned below, will result in a longer time to
complete a task, and may result in higher levels of
vibration exposure. A worn tool will also cause
increased working time.
Make sure that the inserted tool is
well-maintained, not worn out and of the proper
size.
Always use a sharp tool in order to work
efficiently.
Checking for wear on the tool shank
Use the gauge that corresponds to the insertion
tool s shank dimension. See section "Technical data"
for correct tool shank dimensions.
9800 0798 90a | Original instructions
The wide bladed chisel is used
in soft materials, such as
asphalt and frozen ground.
www.CrowderSupply.com • Toll Free: 888-883-5144
Safety and operating instructions
>
Check if the gauge s hole (A) can be pushed down
on the insertion tool s shank, this means that the
shank is worn out and the insertion tool should
be replaced.
>
Check the length (B), that it is according to the
ordered machine type.
Fitting and removing the insertion tool
Whenever fitting or removing the insertion tool the
following instructions must be observed:
1. To prevent an accidental start: switch off the
power supply and bleed the machine by
pressing the start and stop device. Disconnect
the machine from the power source.
2. Before inserting a tool, lubricate the tool shank
with grease.
3. Fit or remove the insertion tool.
4. Close the tool retainer (position A) and check
the lock function by tugging the inserted tool
sharply outwards.
Operation
WARNING
Involuntary start
Involuntary start of the machine may cause injury.
Keep your hands away from the start and stop
device until you are ready to start the machine.
Learn how the machine is switched off in the event
of an emergency.
Stop the machine immediately in all cases of
power supply interruption.
15

Publicité

loading

Ce manuel est également adapté pour:

Cp 0112 sCp 0112 ex