Declaration of Performance
TT80-CPR-2018-Version 6
Product:
Product type/application:
Type:
Fuel:
Productions no.
Manufacturer:
Certification and requirements:
AVCP system:
European standard:
Certification:
Declared performance:
Essential characteristics
Reaction to fire
Distance to combustible materials Rear:
Emission of combustion products
Electrical safety
Maximum operating pressure
Risk of burning fuel falling out
Surface temperature
Clean ability
Mechanical strength
Emission of hazardous materials
Flue gas temperature
Output
Energy efficiency
The undersigned is responsible for the manufacturing and conformity with the declared performance.
Viby 17.12.2018
42
Room heater burning solid fuel without hot water supply
TT80: S01-680 Black
TT80: S01-681 Grey
TT80S: S01-682 Black
TT80S: S01-683 Grey
Wood
Please see nameplate on the back of the oven
TermaTech A/S
Gunnar Clausens Vej 36
8260 Viby J
Denmark
System 3
DS/DIN/EN 13240:2001 + A2:2004/ AC2007
Technologic Institute,
notified body no. 1235, has performed determination of the
product type and declared performance on the basis of type testing and issued test
report no. 300-ELAB-2358-EN.
AI
Sides:
To the corner 45⁰ min. 50 mm
Other safety distances – please see User
and mounting manual
CO = 0,076%
NOx = 86 mg/m³
OGC = 85 mgC/Nm³
PM = 15 mg/m³
NPD
NPD
Passed
Passed
Passed
Passed
Passed
245° Celsius
5,5 KW
81 %
Søren Toft______________________________
E-mail:
info@termatech.com
Web:
www.termatech.com
Tel.:
+45 8742 0035
Performance
min. 75 / 50 mm
min. 300 mm
Harmonised technical
specification
DS/DIN/EN
13240:2001+A2:2004/
AC2007