E N G L I S H
The laser beam passes through the red plastic surface and is reflected by
the reflective rear side of the card. Supporting easy use during horizontal
adjustment, the card is marked with inch and metric scales, and has a
stand at the back to place it on the floor.
Optional accessories
Consult your dealer for further information on the appropriate accessories.
Maintenance
Your D
WALT power tool has been designed to operate over a long period
E
of time with a minimum of maintenance. Continuous satisfactory operation
depends upon proper tool care and regular cleaning.
Field calibration check (fig. G1 - G3)
The field calibration check must be performed securely and accurately to
make a correct diagnosis. Whenever an error is registered, have the tool
serviced by a qualified repair agent.
The conditions of the area are indicative of the results
presented. If the practice differs from these conditions,
the measurements have to be adjusted accordingly.
• Place the tool in an area of at least 10 m by 5 m. Position the tool so
that it is aimed front-to-back towards the short walls.
• Place the tool at approximately 10 cm from the wall as measured from
the rear of the tool. Mark the intersection point of the laser lines (8).
• Switch on the tool. Mark the centre of the laser line (9) pointing forward
on the opposite short wall.
• Locate the position of the laser beam halfway between the short walls
using a target. Mark this point (10) on the floor. Switch off the tool.
• Move the tool in a straight line to the floor marking (10).