Manufacturer warrants, to the purchaser and subsequent owner
during the warranty period, every new product to be free from
defects in material and workmanship under normal use and service,
when properly used and maintained, for a period of one year from
date of purchase by the end user, or 18 months from date of original
manufacture of the product, whichever comes first. Parts that fail
within the warranty period, one year from date of purchase by the
end user, or 18 months from the date of original manufacture of the
product, whichever comes first, that inspections determine to be
defective in material or workmanship, will be repaired, replaced or
remanufactured at Manufacturer's option, provided however, that
by so doing we will not be obligated to replace an entire assembly,
the entire mechanism or the complete unit. No allowance will be
made for shipping charges, damages, labor or other charges that
may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for
any material or product that has been disassembled without prior
approval of Manufacturer, subjected to misuse, misapplication,
neglect, alteration, accident or act of nature that has not been
installed, operated or maintained in accordance with Manufacturer's
installation instructions; that has been exposed to outside substances
including but not limited to the following: sand, gravel, cement, mud,
tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents,
etc.), or other abrasive or corrosive substances, etc. in all pumping
applications. The warranty set out in the paragraph above is in lieu
of all other warranties expressed or implied; and we do not authorize
any representative or other person to assume for us any other liability
in connection with our products.
ELECTRICAL PRECAUTIONS - B efore servicing a pump, always shut off the main power breaker and then unplug the
pump - making sure you are not standing in water and wearing insulated protective sole shoes. Under flooded conditions, contact your
local electric company or a qualified, licensed electrician for disconnecting electrical service prior to pump removal.
Submersible pumps can become pressurized under normal operating conditions. Allow 2-1/2 hours after disconnecting
before attempting service.
CONDITION
A. Pump will not start or run.
Motor overheats and trips
B.
overload or blows fuse.
Pump starts and stops too
C.
often.
D. Pump will not shut off.
Pump operates but delivers
E.
little or no water.
Drop in head and/or capacity
F.
after a period of use.
G. If tank or fittings leak.
If the above checklist does not uncover the problem, consult the Product Support Department; do not attempt to service or otherwise disassemble
pump. Service must be by Zoeller Authorized Service Stations. Visit www.zoellerpumps.com for Service Station listing.
LIMITED WARRANTY
SERVICE CHECKLIST
COMMON CAUSES
Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically,
or relay when used, motor or wiring shorted. Float assembly held down. Switch defective, damaged, or out of
adjustment.
Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically,
relay or motor shorted.
Float switch tether length too short, check valve stuck, or none installed in long distance line or overload open.
Debris under float assembly, float bound by basin sides or other, damaged or out of adjustment.
Check pump inlet, discharge pipe, and weep holes for obstructions. System head exceeds pump capacity. Low
or incorrect voltage. Capacitor defective. Incoming water containing air or causing air to enter pumping chamber.
Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly
deteriorate impeller and pump housing. Check line. Inspect pump inlet.
Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do not over
tighten fittings or screws.
© Copyright 2019 Zoeller
2
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky
40211, Attention: Product Support Department to obtain any needed
repair or replacement of part(s) or additional information pertaining
to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED
TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.
Co. All rights reserved.
®