Notice to Installer: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
Patent No. 9,004,381
Other Patents Pending
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs
from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future
reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle of
grounding type must be installed and protected by a ground fault circuit
interrupter (GFCI) and in accordance with National Electrical Code and local
codes.
2. Make certain that the receptacle is within the reach of the pump's power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are
too long or too light do not deliver sufficient voltage to the pump motor and
they could present a safety hazard if the insulation were to become damaged
or the connection end were to fall into a wet or damp area.
3. Testing for ground. As a safety measure, each electrical outlet should be c hecked
for ground using an Underwriters Laboratory Listed circuit analyzer which will
indicate if the power, neutral and ground wires are correctly connected to your
outlet. If they are not, call a qualified electrician.
4. For Added Safety. Pump must be connected to a 3-prong grounded outlet
interrupter device (ground fault circuit interrupter).
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE
BEFORE HANDLING. Single phase pumps are supplied with a 3-prong grounded
plug to help protect you against the possibility of electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. To reduce the risk of
electrical shock, a properly grounded receptacle of grounding type must be
installed and protected by a ground fault circuit interrupter (GFCI) in accordance
with national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware should only be
performed by a qualified, licensed electrician.
7. Risk of electric shock. These pumps have not been investigated for use in
swimming pool or marine areas.
8. Prop65 Warming for California residents: Cancer and Reproductive Harm- www.
P65Warnings.ca.gov.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
915 GRINDER PACKAGE
(Preassembled)
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
© Copyright 2019 Zoeller
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
1. Check to be sure your power source is adequate for handling the voltage
requirements of the motor, as indicated on the pump or basin plate.
2. Make sure the pump electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized
according to the National Electrical Code for the current shown on the pump
name plate.
3. All plumbing (discharge and vent lines) must be installed to meet local codes.
Unit must be vented. Some states require this unit to be installed by a qualified
licensed plumber. DO NOT USE AN AUTOMATIC PLUMBING VENT DEVICE SIMILAR
TO A "PRO-VENT".
4. Repair and service should be performed by Zoeller Pump Company Authorized
Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY CYCLING OF PUMP.
6. Maximum operating temperature for 915 Grinder Pumps must not exceed
110 °F (43 °C).
7. For health reasons, do not unplug, turn off, or disable pump and use pump tank
system as a way to fill up a sink or laundry tray, etc.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL
Standard UL778. CSA Certified pumps are certified to CSA Standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
FM2671
0419
Supersedes
1217
Visit our web site:
zoellerpumps.com
MODEL:_______________________
DATE CODE: __________________
DATE INSTALLED: _____________