Notice to Installer: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
Patent No. 9,004,381
Other Patents Pending
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs
from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future
reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle of
grounding type must be installed and protected by a ground fault circuit
interrupter (GFCI) and in accordance with National Electrical Code and local
codes.
2. Make certain that the receptacle is within the reach of the pump's power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are
too long or too light do not deliver sufficient voltage to the pump motor and
they could present a safety hazard if the insulation were to become damaged
or the connection end were to fall into a wet or damp area.
3. Testing for ground. As a safety measure, each electrical outlet should be c hecked
for ground using an Underwriters Laboratory Listed circuit analyzer which will
indicate if the power, neutral and ground wires are correctly connected to your
outlet. If they are not, call a qualified electrician.
4. For Added Safety. Pump must be connected to a 3-prong grounded outlet
interrupter device (ground fault circuit interrupter).
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE
BEFORE HANDLING. Single phase pumps are supplied with a 3-prong grounded
plug to help protect you against the possibility of electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. To reduce the risk of
electrical shock, a properly grounded receptacle of grounding type must be
installed and protected by a ground fault circuit interrupter (GFCI) in accordance
with national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware should only be
performed by a qualified, licensed electrician.
7. Risk of electric shock. These pumps have not been investigated for use in
swimming pool or marine areas.
8. Prop65 Warming for California residents: Cancer and Reproductive Harm- www.
P65Warnings.ca.gov.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
915 GRINDER PACKAGE
(Preassembled)
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
© Copyright 2019 Zoeller
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
1. Check to be sure your power source is adequate for handling the voltage
requirements of the motor, as indicated on the pump or basin plate.
2. Make sure the pump electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized
according to the National Electrical Code for the current shown on the pump
name plate.
3. All plumbing (discharge and vent lines) must be installed to meet local codes.
Unit must be vented. Some states require this unit to be installed by a qualified
licensed plumber. DO NOT USE AN AUTOMATIC PLUMBING VENT DEVICE SIMILAR
TO A "PRO-VENT".
4. Repair and service should be performed by Zoeller Pump Company Authorized
Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY CYCLING OF PUMP.
6. Maximum operating temperature for 915 Grinder Pumps must not exceed
110 °F (43 °C).
7. For health reasons, do not unplug, turn off, or disable pump and use pump tank
system as a way to fill up a sink or laundry tray, etc.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL
Standard UL778. CSA Certified pumps are certified to CSA Standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
FM2671
0419
Supersedes
1217
Visit our web site:
zoellerpumps.com
MODEL:_______________________
DATE CODE: __________________
DATE INSTALLED: _____________

Publicité

loading

Sommaire des Matières pour Zoeller 915

  • Page 1 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 Register your zoellerpumps.com TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624 Zoeller Pump Company Product on our website: http://reg.zoellerpumps.com/ 915 GRINDER PACKAGE MODEL:_______________________ DATE CODE: __________________ (Preassembled) DATE INSTALLED: _____________ Patent No. 9,004,381 INSTALLATION INSTRUCTIONS...
  • Page 2 If the above checklist does not uncover the problem, consult the Product Support Department; do not attempt to service or otherwise disassemble pump. Service must be by Zoeller Authorized Service Stations. Visit www.zoellerpumps.com for Service Station listing. © Copyright 2019 Zoeller Co.
  • Page 3 DO always connect to a separately protected and properly 6. DO review all applicable local and national codes and verify that the installation conforms to each of them. grounded ground fault protected circuit. DO NOT ever cut, splice or damage power cord. DO NOT carry or lift pump by its power cord. DO NOT use an extension cord. 915 GRINDER FEATURES ® cutter technology - three independant cutting channels provide over 250,000 cuts/minute. Tri-Slice IBAD - Integral Baffling and Deflection System ®...
  • Page 4 SYSTEM MUST BE ORIENTED position and complete plumbing. Secure all WITH DIRECTION LABEL connections shown in Figure 1. RELATIVE TO THE INLET. Attach check valve to the discharge pipe above cover. SK2896 Figure 1 ILLUSTRATED PARTS BREAKDOWN MODEL : 915 - A 915 - B 8/11 12/11 ITEM DESCRIPTION thru thru 11/11 Current HARDWARE KIT - STD/10' (3 M) STACK...
  • Page 5 Registre en línea DIRECCIÓN PARA ENVÍOS: 3649 Cane Run Road • Louisville, KY 40211-1961 EEUU zoellerpumps.com su producto de TEL: +1 (502) 778-2731 • FAX: +1 (502) 774-3624 Zoeller Pump Company: http://reg.zoellerpumps.com/ MODELO:_____________________ PAQUETE DE BOMBA CÓDIGO DE FECHA: ____________ FECHA DE INSTALACIÓN: ________...
  • Page 6 Si la lista de verificación arriba mencionada no revela el problema, consulte con el departamento de Apoyo al producto de Zoeller. No intente proporcionar algún servicio o desarmar la bomba. Las estaciones de servicio autorizadas por Zoeller deberán proporcionar dicho servicio. Visite www.zoeller.com para ver la lista completa de centros de servicio.
  • Page 7 SIEMPRE conecte la bomba a un circuito protegido separadamente y con puesta a tierra adecuado. NO corte, empalme o dañe el cable de alimentación eléctrica. NO transporte o levante la bomba por su cable de alimentación eléctrica. NO use un cable de extensión. CARACTERÍSTICAS DEL TRITURADOR 915 Tecnología de cortador Tri-Slice – tres canales de corte independientes que dan más de 250,000 cortes/minuto. ® ) – sistema que deja entrar sólidos al contenedor para agua de hasta 102 mm (4 pulg.) sin que ® IBAD (Integral Baffling and Deflection System sedimenten y minimiza la posible obstrucción del flotador.
  • Page 8 RESPECTO A LA ENTRADA. se muestra en la Figura 1. Conecte la válvula de retención a la tubería de descarga encima de la tapa. SK2896 Figura 1 DESGLOSE ILUSTRADO DE PIEZAS MODELO : 915 - A 915 - B 8/11 12/11 COMPONENTE DESCRIPCIÓN CANTIDAD 11/11 Presente JUEGO DE HERRAJES - BAJANTE ESTÁNDAR...
  • Page 9 MODÈLE : _____________________ SYSTÈME COMPLET CODE DATE : _________________ DATE D’INSTALLATION : ________ Brevet n° 9,004,381 DE BROYEUSE 915 En attente d'autres brevets (Préassemblé) INSTRUCTIONS D’INSTALLATION LISTE DE VÉRIFICATIONS AVANT L’INSTALLATION 1. Inspecter tout matériaux. De temps en temps, la pompe est endommagée en cours d’expédition. Si la pompe est endommagée, contacter le distributeur avant de l’utiliser. NE PAS enlever les bouchons test du la pompe.
  • Page 10 Si les vérifications ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. Toutes les répa- rations doivent être faites par un centre de réparation agréé par Zoeller. Visitez le www.zoellerpumps.com pour obtenir la liste des centres d’entretien.
  • Page 11 6. IL F AUT é tudier t ous l es c odes l ocaux e t n ationaux a pplicables 3. IL FAUT toujours débrancher l’alimentation de la pompe avant de et vérifier que l’installation est conforme. la manipuler. IL FAUT toujours brancher la pompe sur un circuit séparé mis à la terre. IL NE FAUT JAMAIS couper, faire une épissure ou endommager un cordon d’alimentation. IL NE FAUT PAS utiliser le cordon d’alimentation pour transporter ou soulever la pompe. IL NE FAUT PAS utiliser de rallonge. CARACTÉRISTIQUES BROYEUSE 915 - Trois circuits de coupe indépendants apportent 250 000 coupes/minute. Technologie de coupe Tri-Slice ® ) – Système de chicanage interne et de déviation qui permet de laisser entrer des solides de 102 mm (4 ® IBAD (Integral Baffling and Deflection System po) dans la cuve sans blocage ; minimise les éventuelles obstructions du flotteur.
  • Page 12 ORIENTÉ À L’AIDE DE L’ÉTIQUETTE DE terminer la plomberie. Sécuriser tous les DIRECTION PAR raccords comme indiqué sur la figure 1. RAPPORT À L’ENTRÉE. Fixer un clapet antiretour au tuyau d’évacuation au-dessus de l’angle. SK2896 Figure 1 SCHÉMAS ÉCLATÉS MODÈLE : 915 - A 915 - B 8/11 12/11 ARTICLE DESCRIPTION QUANTITÉ à travers à travers 11/11 Courant KIT DE MATÉRIEL - COLONNE STANDARD 151846...