LCS A1 V05 progr. functions
GB
7.2 LCS A1 V05 PROGRAMMABLE FUNCTIONS
Here below are indicated the programmable
functions
of
LCS
programming menu and options in which are
pointed out in bold type the standard parameters
settled with Computer new or resetted.
- NUMBER OF CYLINDER / TYPE OF IGNITION:
DOUBLE-COIL, SINGLE-COIL, 4/5/6/8 CYLINDERS
- RPM SIGNAL:
STANDARD, WEAK
- PETROL/GAS AUTOMATIC CHANGE:
IN
DECELERATION,
STARTING (only if enabled)
- PRIMING TIME: (only if enabled gas starting)
0,0 – 5,0 sec (0,8 sec)
- TEMPERATURE FOR CHANGE: (only if enabled)
20° - 40° (30°)
- RPM FOR AUTOMATIC CHANGE:
400 - 9.000 RP
(2.000 RPM)
- FUEL OVERLAPPING TIME DURING AUTOMATIC
CHANGE:
0,000 - 1,000 SEC. (0,400 SEC.)
- TPS (THROTTLE POSITION SENSOR):
LINEAR 0-5V, LINEAR 5 - 0V, SWITCH 0 - 12V,
SWITCH 12 - 0V, MONO BOSCH, TPS ADAPTER
- GAS LEVEL SENSOR:
LANDI RENZO, A.E.B., 0-90 OH
- LAMBDA SENSOR:
0 - 1V, 0,8 - 1,6V, 0 - 5V 'A', 0 - 5V 'B',
5 - 0V 'A', 5 - 0V 'B,
- LAMBDA SENSOR READING DELAY:
0 - 1.250 SEC. (5 SEC.)
- LAMBDA SENSOR EMULATION:
SQUARE WAVE, DISCONNECTED, GROUND
- SQUARE WAVE EMULATION (only if selected previous
option): HIGH TIM (0,36 SEC.), LOW TIME (0,36 SEC.),
DISCONNECTED SENSOR TIME (0,00 SEC.), NUMBER
OF WAVES AFTER DISCONNECTION (0)
- ACTUATOR-MAX DEVIATION IN ACCELERATION:
NOT ENABLED, 40 - 240 STEPS (100 STEPS if
enabled)
- TPS DURING DEVIATION: (only if selected previous
option) 1,5 - 5,0V (2,8V)
INSTALLATION AND ADJUSTMENT MANUAL LAMBDA CONTROL SYSTEM A1 V05
All manuals and user guides at all-guides.com
A1
V05
with
relevant
IN
ACCELERATION,
LANDI RENZO S.p.A.
LCS A1 V05 programmation
Malfunctioning diagnosis
- ACTUATOR-MAX HIGH POSITION:
20 - 240 STEPS (240 STEPS )
- TPS TO RELEASE LIMITATION: (only if selected
relevant options) 0,0 - 5,0V (2,8V)
- ACTUATOR-MAX LOW POSITION:
20 - 240 STEPS (20 STEPS )
- CUT-OFF OPTION:
NOT ENABLED, ENABLED
- MINIMUM RPM FOR CUT-OFF: (only if selected
previous option) 400 - 9.000 RP
GAS
- ACTUATOR-MAX POSITION FOR CUT- OFF: (only if
selected previous option) 40 - 240 STEPS (80 STEPS)
- ACTUATOR-MAX INCREASE IN ACCELERATION:
NOT ENABLED, ENABLED
- TPS DEVIATION FOR INCREASE: (only if selected
previous option) 0,1 - 3,0V (0,3V)
- NUMBER STEPS FOR INCREASE: (only if selected
previous option) 0 - 30 STEPS (5 STEPS)
- ACTUATOR-MAX POSITION FOR FIXED DEFAULT:
NOT ENABLED, 20 - 240 STEPS
enabled)
- LCS A1 V05 MEMORY RESETTING: OK TO CONFIRM
allows to re-set the standard values (in bold type) of LCS
A1 V05 Computer
7.3 NOTES CONCERNING THE LCS A1 V05
PROGRAMMATION
The standard emulation of the lambda sensor is
settled
as
TYPE
EMULATION Ì SQUARE WAVE. This kind of
emulation is used for the main part of the vehicles
and must be changed only if allowed from the
TECHNICAL MANUAL LANDI RENZO MT012.
The lambda sensor emulation of vehicles with
Monoinjector Bosch (for which the parameter
TYPE OF TPS Ì MONO BOSCH) is made
programming
EMULATION Ì GROUND. On this vehicles the
yellow-blue wire of LCS A1 V05 must be
connected to the wire n. 2 (and not to the wire n.
4) of the TPS connector at side of the throttle
body.
18 / 33
(1.500 RPM)
(100 STEPS if
OF
LAMBDA SENSOR
the
parameter TYPE OF