Assembly instructions
I. Description
3.
1
Luminaire
2 PIR sensor
3 Sensor fixing screw
4.
4 Light control
5.
5 Detection distance
6 Time setting
6.
7 Wall mount
7.
8 Angle fixing screw
9 Power cable
10 Connection terminal
11 Screw cap
8.
9.
10.
11.
II. Assembly
1. Select an installation location without pipes or cables behind it. Mark the fastening holes, and
drill the holes for the clamps. Ensure that these are positioned according to the fixing slots in
the wall mount.
2. Insert the plugs, and fix the luminaire with the screws.
Caution: Make sure the fasteners are suitable for the wall material.
3. Adjust the luminaire 1 in the desired angle. If necessary, loosen the angle fixing screws 8 and
tighten them again.
4. To change the angle of the motion detector loosen the sensor fixing screw 3. Re-tighten the
screws after adjustment.
5. Connect the luminaire 1 to the power supply (see section III).
36
III. Connection
Caution:
First disconnect the power supply for this connection.
Disassemble the connection terminal 10. Remove 8 mm of insulation from each cable. Push
1
cable through the cable inlet and connect the luminaire 1 to the power supply (see figure).
2 Fix the cables by tightening the screws. Make sure that the connections are tight and that no
loose cable endings emerge from the terminal.
N:
Blue
L:
Brown
:
Yellow/Green
3 Reassemble the connection terminal 10 and tighten the screw cap 11 with 10 Nm. Make sure
the cable insulation reaches well within the connection terminal 10.
Connect the power supply.
IV. Settings
1. TIME: Change the lighting time from 10 s to 10 min.
2. SENS: Detection range of the motion detector (160°, max. 10 m).
3. LUX:
Define the ambient luminance level below which the lamp is activated (day/night).
The luminaire turns on automatically when movement is detected in the
sensing area and the ambient luminance is below the adjusted level. It
will stay lighted for 10 s - 10 min, depending on the settings. High temperatures
or strong light interference could cause malfunctions.
V. Maintenance and care
Cleaning
Wipe the luminaire with a soft, damp cloth only. Never use scouring powders or chemical cleaning
agents. Never allow the electrical components to become damp.