ERROR CODES:
Error code
F1
The power supply voltage is too low.
F2
The condenser fan is overloaded.
F3
The compressor turns on too often.
F4
The compressor does not turn on.
Overheating of the compressor and
F5
electronics.
The controller does not read the
F6
parameters of the device.
F7 or F8
The temperature sensor is defective.
Possible cause
Action
Switch the battery protection mode from high
to medium or from medium to low
Disconnect the power for 5 minutes and turn
the device on again. If the problem reappears,
contact the service center.
Disconnect the power for 5 minutes and turn
the device on again. If the problem reappears,
contact the service center.
Disconnect the power for 5 minutes and turn
the device on again. If the problem reappears,
contact the service center.
Disconnect the power for 5 minutes and turn
the device on again. If the problem reappears,
contact the service center.
Disconnect the power for 5 minutes and turn
the device on again. If the problem reappears,
contact the service center.
Contact service center