2.
Now lift out the dust container.
3.
Turn the dust container cover carefully (J) until it is released and the HEPA filter will
come away easily (K).
4.
Now rinse the HEPA filter under running water and allow it to dry (L).
Caution! Only ever clean the filter with clean water and do not use soap or detergent.
These would destroy the filter.
5.
Place the HEPA filter back in the HEPA cover (or replace with a new one) and fit it into
the dust container. Then fit the dust container back into position in the cyclone dust
container until it snaps into place. Your cyclone vacuum cleaner is now ready for use
again.
Motor protection valve
The unit has the protection valve, when the dust cup is full of dust , HEPA filter is blocked or the
air path is blocked, the protection valve will turn on automatically avoiding motor over-heat in
order to prolong the life of motor.
Cleaning the other parts of the vaccum cleaner
The casing, dust collecting chamber and filter chambers of the vacuum cleaner can be wiped
with a damp cloth if required. No liquid must enter the vacuum cleaner in the process. Never
use strong cleaning substance(scouring liquids, thinners), since these will corrode the plastic
surface. Only place the plug back in the mains socket when you have made sure that all the
parts are thoroughly dry.
Hair and fluff may gather on the running wheels and on the floor nozzle of the vacuum cleaner
in time.
You should remove these to ensure that handling of the vacuum cleaner is always easy.
Note! Lubricating or oiling of the roller bearing is not recommended, because this will cause dirt
and fluff to stick even better.
PRACTICAL HINTS
When cleaning stairs, we advise you to keep the unit in a vertical position.
The floor brush is equipped with a hook, allowing you to attach the tube to the rear part of
the appliance when it is in use, for instance when you want to move a piece of furniture,
or after use when storing your appliance.
The vacuum cleaner requires no regular maintenance other than the filter cleaning tasks
as detailed here above.
TROUBLE-SHOOTING
Faults can occur on all electrical equipment. This must not necessarily be due to a defect in
the device itself. So check first with table if the fault can be dealt with.
PROBLEM
Weak suction
All manuals and user guides at all-guides.com
Copies of the I/B. Please reproduce them without any
changes
except
International BELGIUM. The pages must be reproduced and
folded in order to obtain a booklet A5 (+/- 148.5 mm width x
210 mm height). When folding, make sure you keep the good
numbering when you turn the pages of the I/B. Don't change
the page numbering. Keep the language integrity.
POSSIBLE CAUSES
The secondary valve is
open.
An object is blocking the
suction pipe
Filters are not fitted
properly or are blocked
65
Assembly page 65/67
under
special
instruction
SOLUTIONS / TIPS
Close the secondary valve
Check the suction tube, the
handle area, suction pipe and
the nozzle in use for blockages.
Fit a new filter
TKG VC 1022 - 170214