Cleaning with your high-pressure cleaner
If necessary, first clean the object from coarse soil in high-pressure mode.
•
Spray the detergent onto the surface and allow it to soak in. Do not leave it to dry.
•
•
Spray off the loosened soil in high-pressure mode.
Fan Nozzle
By twisting the nozzle casing (21) the flow can be adjusted between jet (19) and spray (20)
via the fan nozzle.
Rotor Nozzle
The rotor nozzle (11) creates a rotating jet of water. This can be used to achieve rapid
cleaning of large areas of the ground or walls.
First follow the instructions above under the heading "Before Using Equipment".
•
Mount the rotor nozzle (11) onto the spray lance (6) as described earlier.
•
When the trigger (14) is pressed a rotating jet is produced.
•
Using the trigger gun in a sweeping motion algae and moss, for example, can be
•
removed from exterior surfaces.
Finishing the Cleaning Process
Switch off high-pressure cleaner by turning the operating switch (3) to "OFF" and
•
disconnect the mains plug.
•
Turn off the water supply and disconnect the equipment from the water supply.
Squeeze the gun trigger (14), until the equipment is depressurised.
•
Lock the gun trigger (14) with the trigger lock (13).
•
Disconnect the high-pressure hose (8) from the spray gun (1) by pressing the release
•
button (15), and remove the tube from the gun by pulling downwards.
Store equipment in a secure location that is frost-free and out of the reach of children.
•
Before longer periods of disuse and storage during the winter, allow to run for about 5
•
seconds without any water supply and with the high pressure hose disconnected. By
doing this, the pump will be emptied of as much of the remaining water as possible,
which will virtually remove the risk of damage due to water freezing inside the
equipment.