All manuals and user guides at all-guides.com
Introduction
Input/Output Connector
This connector has input and output ports for RS-485 control signals, DAY/NIGHT switching, and alarm
output signals.
No.
1
2
3
4
5
6
7
8
9
10
SETUP Switch
This switch is used to set the function or property. When this switch is pressed for at least 2 seconds, the
MAIN MENU appears.
(Left/Right) : By pressing this switch left or right, you can move left or right on the menu or change the
(Up/Down) : By pressing this switch up or down, you can move up or down on the menu.
: When you press this switch in the menu, the selected function is confi rmed. To enter a submenu, press
this button.
Power Display LED
When the power is normally connected, the red LED lights.
Video OUT Port
This is connected to the Video Input Port of the monitor and it outputs the Video signals.
GND
This is a grounding port.
Power Connection Port
This is connected to the Power cable.
10 – DIGITAL COLOR CAMERA
Function
ALARM OUT
GND
GND
SHUTTER (S0)
SHUTTER (S1)
SHUTTER (S2)
5V OUT
DAY/NIGHT IN
RS-485 DATA-
RS-485 DATA+
displayed value.
Alarm out port for motion detection. (Open collector type)
Grounding Port.
Grounding Port.
This is a port for selecting an external high speed shutter mode.
If connected in LOW (0V), it will become ON inside.
This is a port for selecting an external high speed shutter mode.
If connected in LOW (0V), it will become ON inside.
This is a port for selecting an external high speed shutter mode.
If connected in LOW (0V), it will become ON inside.
Power supply port for RS-485 JIG. Use within typical DC +5V 100mA
This is a port for DAY&NIGHT conversion.
High(DC +3V~+5V) : DAY(COLOR) Mode,
Low(0V) : NIGHT(BW) Mode
This is a port for connection to RS-485 DATA- signal line.
This is a port for connection to RS-485 DATA+ signal line.