Télécharger Imprimer la page

T.I.P. Maxima 400 SX Mode D'emploi page 11

Pompe submersible pour eaux usées
Masquer les pouces Voir aussi pour Maxima 400 SX:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Any nonobservance of this instruction bears the risk of an electrical shock which may
cause damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer
has to be informed immediately, at the latest within 8 days after the date of purchase.
2. Range of use
Submersible dirty water pumps from T.I.P. are highly efficient electrical pumps for discharging clear or
dirty water containing solids up to the maximum size specified in the technical details. These high-
quality products with their convincing performance data were developed for the multiple purposes
involved with draining and pumping liquids from one place to another.
Typical applications for waste water submersible pumps are: Emptying ponds, tanks, storage tanks,
and waste water pits, as well as emergency drainage in the event of flood or high water.
Submersible dirty water pumps from T.I.P. are suitable for stationary or temporary installations.
This product is intended for private use in the home area and not for commercial or industrial purposes
or for continuous circulating.
The pump is not suitable for use in table-top fountains, aquariums or similar ranges of use.
When using the unit in a pond, please take the required action to ensure that no inhabitants of the
pond will be sucked in.
The pump is not suited to discharge saltwater, faeces, inflammable, etching,
explosive or other hazardous liquids. Please observe the max. temperature of the
liquids to be discharged stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being
discharged in case of any improper operation or damage of the device. The
lubricants used are biologically degradable and non-hazardous to health.
3. Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
2)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
4. Scope of delivery
The scope of the delivery of this product includes:
One pump with connection cable, two connection ports, one reducing part, one operating manual.
Maxima 400 SX
230 V ~ 50 Hz
950 Watt
IP 68
45.48 mm
, female
(1 ½ ")
24,000 l/h
0.9 bar
9 m
7 m
35 mm
35° C
30, evenly distributed
10 m
H07RN-F
13.8 kg
110 mm
40 mm
450 mm
250 mm
16 x 18 x 44 cm
30140
2
9

Publicité