EN
2
3
Setting the valve home position
Home position:
- check that the home position of the valve
is closed.
- make sure the position indicator slot is
across to the pipe axis.
5
Manual operation
Fixate the
drive
The valve can be opened using the enclosed
crank. For that plug crank in hex and rotate
counterclockwise. This position can be fixed
with a cross head screwdriver if necessary.
18 /60 – K410068601001-00 / 01.2024 – © www.kemper-group.com
Installation
Mount the spring-
reset at the drive
4
Fixate the servo drive on the valve
Fixate the servo drive using an 10 mm
hexagonal wrench (allen key), tightening
torque 7....9 Nm.