Figure 6
SECTION 5
Wiring
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING:
THIS UNIT MUST BE WIRED ON A SEPARATE
15 AMP CIRCUIT.
WARNING:
USE APPROPRIATELY SIZED COPPER
CONDUCTORS ONLY RATED FOR AT LEAST 75°C.
CAUTION:
ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE
THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Run wiring from wall switches carrying the appropriate rating.
One neutral (white), one ground (green or bare copper), and
three hot (red, blue, and yellow leads connected to the switch,
one for each function). Secure the electrical wires to the
housing with an approved electrical connector. Make sure
you leave enough wiring in the box to make the connection
to the fan's receptacles.
2. Connect the White wire from the house to the three White
wires from the fan. Connect one Hot (Blue) wire from the
wall switch to the Blue wire from the fan (this is the fan
control). Connect second Hot (Red) wire from the wall switch
to the Red wire from the fan (this is the heat control). Connect
the third Hot (Yellow) wire from the wall switch to the Yellow
wire from the fan (this is the light control). Connect the ground
wire from the house to the Green wire from the fan (Figure
7). Use approved methods for all connections.
Ground
Hot (Blue)
Hot (Yellow)
Hot (Red)
Figure 7
210575055 Rev. A 8-06
Neutral (White)
SECTION 6
Completing the Installation
1. Reinstall the fan's venturi by holding it at approximately a 45
degree angle, hook the two tabs on the venturi into the slots
on the housing and secure in place by tightening the venturi
screw. Rotate the blower wheel by hand to ensure it spins
freely (Figure 8).
Figure 8
2. Insert the plug from the heating unit into the receptacle marked
"HEAT", and the plug from the fan into the receptacle marked
"VENT"(Figure 9).
Figure 9
3. Remove grill from carton and open light lens area by pushing
in on the two tabs of the light lens and pulling outward from
lens. The lens will swing open on the connector bars. DO NOT
remove the lens from the grill (Figure 10).
Connector Bar
Figure 10
www.airkinglimited.com
Vent
Heater
Tabs