Télécharger Imprimer la page

Bruder Mannesmann Werkzeuge 12716 Instructions De Service page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Charging modes
Display
Discription
6 Volt mode
Charging program for 6 V batteries, 1.2 Ah to 14 Ah, temperatures above
0°C, charging current: 2 A maximum, charge voltage: 7.2 V
6 Volt winter mode
Charging program for 6 V batteries, 1.2 Ah to 14 Ah, temperature below 0°C
charging current: 2 A maximum, charge voltage: 7.4 V
Motorbike mode
Charging program for 12 V batteries from 1.2 Ah to 14 Ah, temperatures
above 0°C, charging current: 2 A maximum, charge voltage: 14.6 V
Motorbike winter mode
Charging program for 12 V batteries from 1.2 Ah to 14 Ah, temperatures
below 0°C, charging current: 2 A maximum, charge voltage: 14.8 V
Car mode
Charging program for 12 V batteries from 14 Ah to 120 Ah, temperatures
above 0°C, charging current: 4 A maximum, charge voltage: 14.6 V
Car winter mode
Charging program for 12V batteries from 14 Ah to 120 Ah, temperatures
below 0°C, charging current: 4 A maximum, charge voltage: 14.8 V
Battery maintenance charge mode
As soon as the battery is fully charged, the charger switches over
automatically to battery maintenance charge mode. This is indicated
appropriately on the display.
Error messages
Display
Discription
Display of error after faulty connection (wrong poles), short-circuit,
selection of an incorrect charging programme or overheating.
Error message in 6 V – mode, if a battery is connected with less than 5.5 V
± 0.2 or the voltage is still lower than 6 V after 5 hours of charging time. In
this case, the battery is defective and must be replaced.
.
GB - 10

Publicité

loading