Push the wireless activation button on the tool
4.
briefly. The wireless activation lamp will blink in blue.
► Fig.36: 1. Wireless activation button 2. Wireless
activation lamp
Pull the switch trigger of the tool. Check if the
5.
vacuum cleaner runs while the switch trigger is being
pulled.
To stop the wireless activation of the vacuum cleaner,
push the wireless activation button on the tool.
Description of the wireless activation lamp status
► Fig.37: 1. Wireless activation lamp
The wireless activation lamp shows the status of the wireless activation function. Refer to the table below for the
meaning of the lamp status.
Status
Color
Standby
Blue
Green
Tool
registration
Cancelling
Red
tool
registration
Others
Red
Off
Cancelling tool registration for the
vacuum cleaner
Perform the following procedure when cancelling the
tool registration for the vacuum cleaner.
Install the batteries to the vacuum cleaner and the tool.
1.
Set the stand-by switch on the vacuum cleaner to "AUTO".
2.
► Fig.38: 1. Stand-by switch
Press the wireless activation button on the vac-
3.
uum cleaner for 6 seconds. The wireless activation
lamp blinks in green and then become red. After that,
press the wireless activation button on the tool in the
same way.
► Fig.39: 1. Wireless activation button 2. Wireless
activation lamp
If the cancellation is performed successfully, the wire-
less activation lamps will light up in red for 2 seconds
and start blinking in blue.
Wireless activation lamp
On
Blinking
-
NOTE: The wireless activation lamp on the tool will
stop blinking in blue when there is no operation for
2 hours. In this case, set the stand-by switch on the
vacuum cleaner to "AUTO" and push the wireless
activation button on the tool again.
NOTE: The vacuum cleaner starts/stops with a delay.
There is a time lag when the vacuum cleaner detects
a switch operation of the tool.
NOTE: The transmission distance of the wireless unit
may vary depending on the location and surrounding
circumstances.
NOTE: When two or more tools are registered to one
vacuum cleaner, the vacuum cleaner may start run-
ning even if you don't pull the switch trigger because
an other user is using the wireless activation function.
Duration
2 hours
The wireless activation of the vacuum cleaner is available. The
lamp will automatically turn off when no operation is performed
for 2 hours.
The wireless activation of the vacuum cleaner is available and the
When
tool is running.
the tool is
running.
20 seconds Ready for the tool registration. Waiting for the registration by the
vacuum cleaner.
The tool registration has been finished. The wireless activation
2 seconds
lamp will start blinking in blue.
20 seconds Ready for the cancellation of the tool registration. Waiting for the
cancellation by the vacuum cleaner.
The cancellation of the tool registration has been finished. The
2 seconds
wireless activation lamp will start blinking in blue.
The power is supplied to the wireless unit and the wireless activa-
3 seconds
tion function is starting up.
The wireless activation of the vacuum cleaner is stopped.
-
NOTE: The wireless activation lamps finish blinking in
red after 20 seconds elapsed. Press the wireless acti-
vation button on the tool while the wireless activation
lamp on the cleaner is blinking. If the wireless acti-
vation lamp does not blink in red, push the wireless
activation button briefly and hold it down again.
19 ENGLISH