Replacing the cartridge
1. Shut off the water supply to the faucet.
2. Turn on the faucet briefly to relieve any
pressure inside the faucet.
3. Move the faucet handle to the "OFF"
position.
4. Remove the set screw from the Handle
Assembly (A) using a 2.5 mm Hex Key.
5. Pull the Lever Handle (A) from faucet
body.
6. Unscrew the Connector Kit (B) from the
cartridge.
7. Uscrew the Cartridge Lock Nut (C).
8. Lift Ceramic Disc Cartridge (D) from the
body and replace it with a new one.
9. Re-assemble faucet in reverse order.
10. Test for leakage.