4.3 BUTTON FUNCTIONS
A - Power button
B- Button down(DOWN)
C- Up button (UP)
D- TIMER button
4.4 OPERATING INSTRUCTIONS
1. Plug in the unit.
2. Press the
button to start the operation, the power indicator will be on. Press
it again to stop the operation.
3. Press or
button to set the desired humidity level in the room, which can be set from
30% to 90% at 5% intervals or "CO".
After a period of work, when the ambient humidity is lower than the selected humidity by 2%, the
compressor will stop; When the ambient humidity equals or exceeds the selected humidity by 3%,
the compressor will restart after the compressor protection time of 3 minutes ends.
By setting the humidity to "CO", the compressor will run continuously.
4. The push button
It can be the timer setting:
Press the button to set the time the unit turns on and off. If you want to cancel the timer
programming, please press the button to set the time to 0 and press the button, it will cyclefrom 0-
1-2......23-24. Isthe scheduled time to change the machine. The programmed time will be canceled
when the compressor is changed manually each time. The programmed time remains unchanged
if the machine stops due to full water or during defrosting.
15