WIRINGS DIAGRAMS
Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all
panels before operating. Failure to do so can result in electrical shock causing severe injuries or death.
RED
RED
RED
RED
RED
RED
BLK
BLK
BLK
1. If any of the original wire, as supplied, must be
replaced, use the same equivalent wire. Wiring
must comply with applicable codes, ordinances
and regulations.
2. Field wiring must comply with applicable codes,
ordinances and regulations. Use only Class 1
wiring inside furnace compartments.
Line voltage wiring:
UL AWM 1015/1230, 600V, 105°C, VW-1,12AWG;
CSA TEW 600V, 105°C, FT1, 12AWG.
Low voltage wiring: same ratings as high voltage
except 18AWG.
For the use of a two-stage heat thermostat or
an outdoor thermostat, connect between W1
and W2. Make sure that the
switch is set to the Mild
FE0016A
All manuals and user guides at all-guides.com
(
'
)
CONT
D
HEAT 5
KC5
HTL
E
NO
COM
BLK
HEAT 5
24 Vdc
PNK
HEAT 6
KC6
E
HTL
NO
COM
BLK
HEAT 6
24 Vdc
PPL
HTL
E
NO
RED
BLK
HEAT 4
WHT
HTL
E
NO
RED
BLK
HEAT 3
WHT
HTL
E
BLK
NO
RED
HEAT 2
WHT
HTL
E
BLK
NO
RED
HEAT 1
WHT
N
KC1B
WHT
L2
NC
24V~
RED
24Vac
RED
coil
RED
ORG
RED
L1
BRN
BLK
BLK
BLK
C
BLK
BLK
GRN
BRN
G
Critical Characteristic
Season Selector
Position.
WARNING
!
WHT
RLY PWR2
P2-3
PNK
HEAT5
P2-2
PPL
HEAT6
BLK
P2-1
WHT
PNK
HEAT5 IN
Heater
P1-4
PPL
HEAT6 IN
Logic
P1-3
24V
P1-2
regulated
P1-1
BLK
WHT
WHT
HEAT 4
KC4
BLK
COM
PPL
24 Vdc
PPL
HEAT 3
P3-1 P3-2 P3-3 P3-4 P3-5 P3-6 P3-7
KC3
BLK
COM
RED
F + H
PNK
24 Vdc
GRN
PNK
CS
HEAT 2
F
KC2
BLK
RED
COM
NC
CONTINUOUS
SPEED
24 Vdc
BRN
HEAT 1
KC1
SS
BLK
COM
GRY
SEASON
24 Vdc
SELECTOR
GRY
K7
HEAT INDICATOR
PNK
3
1
24 Vdc
LO
VS
RED
BLU
5
4
YEL
VENTILATION SPEED
MED-LO
6
2
TB2
BLU
M
BLK
HI
BLU
MED-HI
MED-LO
YEL
LO
RED
ORG
WIRING COLOR CODE
BLK
BLACK
BLU
BLUE
BRN
BROWN
GRN
GREEN
GRY
GREY
ORG
ORANGE
PNK
PINK
PPL
PURPLE
RED
RED
WHT
WHITE
YEL
YELLOW
FAN MOTOR SPEED COLOR
HI
BLACK
MED-HIGH
BLUE
MED-LOW
YELLOW
LOW
RED
9
GRY
PNK
Open: 93.3°C (200°F)
MRHTL
PNK
YEL
PNK
PPL
YEL
BRN
GRY
YEL
YEL
P3
BOARD POWER
SUPPLY
BLK
P2-8
PPL
RED
P2-7
PPL
GRN
P2-6
P2-5
P2-4
PPL
PPL
P2-3
BLK
GRY
P2-2
21D27
P2
P2-1
K2
K1
K2
UTEC
1139-600/-630
ORG
BLK
Class 2 Tranformer
Prim.: 240V 60Hz
Second.: 24V 60Hz 40VA
LEGEND
C
Capacitor
F1
Fuse
E
Heating Element
KC
Heating Element
Relay
K
Fan Relay
HTL
Auto-Reset
Thermal Protector
MRHTL
Manual Reset
Thermal Protector
M
Fan Motor
TB2
Terminal Block
T
Transformer Class 2
HEAT
Heat
L1, L2
240V Line Supply
N
Neutral
MRHTL
YEL
F1
5 A
24VAC
COMMON OUT
FUSED 24VAC
POWER OUT
CALL FOR
FAN
CALL FOR
COOL.
REVERSING
VALVE
CALL FOR
HEAT 1
CALL FOR
HEAT 2
CALL FOR
COOL 1
P1
T
RED
YEL
BLK
YEL