Télécharger Imprimer la page

Broan NORTRON D Serie Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

WIRINGS DIAGRAMS
Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all
panels before operating. Failure to do so can result in electrical shock causing severe injuries or death.
Open: 93.3°C (200°F)
MRHTL
MRHTL
WHT
WHT
WHT
HTL
E
RED
HEAT 4
HTL
E
RED
HEAT 3
E
HTL
RED
HEAT 2
HTL
E
RED
HEAT 1
N
KC1B
L2
24V~
24Vac
coil
RED
RED
L1
BLK
BLK
C
BLK
G
HTL
E
RED
BLK
HEAT 5
PNK
HTL
E
RED
HEAT 4
HTL
E
RED
HEAT 3
HTL
E
RED
HEAT 2
E
HTL
RED
HEAT 1
N
KC1B
L2
24V~
RED
RED
24Vac
RED
RED
coil
RED
RED
RED
L1
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
G
FE0015A
All manuals and user guides at all-guides.com
(
'
)
CONT
D
HEAT 4
KC4
BLK
NO
COM
BLK
24 Vdc
PPL
WHT
HEAT 3
KC3
BLK
NO
COM
BLK
F + H
PNK
24 Vdc
WHT
PNK
CS
HEAT 2
F
KC2
BLK
NO
COM
NC
BLK
24 Vdc
WHT
BRN
HEAT 1
KC1
BLK
BLK
NO
COM
SEASON SELECT
24 Vdc
WHT
GRY
K7
HEAT INDICATOR
PNK
3
1
24 Vdc
WHT
VS
5
BLU
4
NC
VENTILATION SPEED
MED-LO
6
2
TB2
ORG
YEL
M
BRN
BLK
HI
BLU
MED-HI
MED-LO
YEL
LO
RED
BRN
GRN
ORG
RLY PWR2
WHT
P2-3
PNK
HEAT5
P2-2
HEAT6
P2-1
PNK
HEAT5 IN
P1-4
PPL
HEAT6 IN
P1-3
24V
HEAT 5
P1-2
regulated
KC5
P1-1
NO
COM
BLK
24 Vdc
WHT
HEAT 4
KC4
BLK
NO
COM
BLK
PPL
24 Vdc
WHT
PPL
HEAT 3
KC3
BLK
NO
COM
BLK
F + H
PNK
24 Vdc
WHT
PNK
CS
HEAT 2
F
KC2
BLK
BLK
NO
COM
NC
24 Vdc
WHT
BRN
HEAT 1
KC1
BLK
BLK
NO
COM
SEASON SELECT
24 Vdc
GRY
WHT
K7
HEAT INDICATOR
PNK
3
1
24 Vdc
WHT
VS
BLU
5
4
NC
VENTILATION SPEED
MED-LO
6
2
TB2
ORG
YEL
M
BRN
BLK
HI
BLU
MED-HI
C
MED-LO
YEL
LO
RED
GRN
BRN
ORG
WARNING
!
WHT
PPL
PNK
BRN
GRY
P3
P3-1 P3-2 P3-3 P3-4 P3-5 P3-6 P3-7
RED
BOARD POWER
SUPPLY
GRN
RED
CONTINUOUS
SPEED
BLK
PPL
RED
PPL
SS
GRN
GRY
PPL
PPL
BLK
GRY
21D18/20
P2
LO
RED
YEL
K2
K2
K1
ORG
BLK
Heater
GRY
Logic
PNK
PNK
PNK
PPL
YEL
BRN
WHT
GRY
P3
P3-1 P3-2 P3-3 P3-4 P3-5 P3-6 P3-7
RED
BOARD POWER
SUPPLY
GRN
RED
CONTINUOUS
SPEED
BLK
PPL
RED
PPL
SS
GRN
GRY
PPL
PPL
BLK
GRY
21D23/25
P2
LO
RED
YEL
K2
K2
K1
ORG
BLK
8
YEL
YEL
1. If any of the original wire, as
F1
supplied, must be replaced, use
5 A
the same equivalent wire. Wiring
must comply with applicable codes,
ordinances and regulations.
2. Field wiring must comply with
applicable codes, ordinances and
24VAC
COMMON OUT
regulations. Use only Class 1 wiring
P2-8
FUSED 24VAC
POWER OUT
inside furnace compartments.
P2-7
CALL FOR
FAN
Line voltage wiring:
P2-6
CALL FOR
COOL.
UL AWM 1015/1230, 600V, 105°C,
P2-5
REVERSING
VW-1,12AWG;
VALVE
P2-4
CSA TEW 600V, 105°C, FT1, 12AWG.
CALL FOR
HEAT 1
P2-3
CALL FOR
HEAT 2
P2-2
Low voltage wiring: same ratings as
CALL FOR
high voltage except 18AWG.
COOL 1
P2-1
P1
FAN
MOTOR SPEED
UTEC
1139-600/-630
HI
MED-HIGH
T
RED
YEL
MED-LOW
LOW
BLK
YEL
Class 2 Tranformer
Prim.: 240V 60Hz
Second.: 24V 60Hz 40VA
C
F1
E
KC
K
Open: 93.3°C (200°F)
MRHTL
MRHTL
HTL
YEL
YEL
MRHTL
M
YEL
YEL
TB2
T
HEAT
F1
5 A
L1, L2
N
For the use of a two-stage heat
24VAC
COMMON OUT
thermostat or an outdoor thermostat,
P2-8
FUSED 24VAC
POWER OUT
connect between W1and W2. Make
P2-7
CALL FOR
sure that the
FAN
is set to the Mild Position.
P2-6
CALL FOR
COOL.
P2-5
REVERSING
VALVE
P2-4
CALL FOR
HEAT 1
WIRING COLOR CODE
P2-3
CALL FOR
HEAT 2
BLK
P2-2
CALL FOR
BLU
COOL 1
P2-1
BRN
P1
GRN
GRY
ORG
UTEC
1139-600/-630
PNK
PPL
T
RED
RED
YEL
WHT
BLK
YEL
YEL
Class 2 Tranformer
Prim.: 240V 60Hz
Second.: 24V 60Hz 40VA
Critical Characteristic
COLOR
BLACK
BLUE
YELLOW
RED
LEGEND
Capacitor
Fuse
Heating Element
Heating Element
Relay
Fan Relay
Auto-Reset
Thermal Protector
Manual Reset
Thermal Protector
Fan Motor
Terminal Block
Transformer Class 2
Heat
240V Line Supply
Neutral
Season Select
switch
BLACK
BLUE
BROWN
GREEN
GREY
ORANGE
PINK
PURPLE
RED
WHITE
YELLOW

Publicité

loading