INSTALLATION AND OPERATING INSTRUCTIONS
This furnace has been designed and manufactured to give the
most reliable performance possible. Each unit has been given a
running inspection before shipment to assure that every component
is operating efficiently.
TOP VIEW
1½"
(38 mm)
17" x 17"
(432 mm x 432 mm)
20"
DISCHARGE
(508 mm)
FRONT VIEW
20"
(508 mm)
39"
(991 mm)
FK0003A
GENERAL REQUIREMENTS AND SPECIFICATIONS
1. LOCATION – The furnace should be centrally located to the
heating area.
2. POSITIONS – It can be installed for vertical, horizontal or
downflow operation. When installed horizontally, the furnace
should be positioned such as the door will not end up being on
the top. The door should be on the side of the furnace, to
ensure that the motor bearings are in their designed position.
In vertical downflow installations, use only "L"- or "T"-shaped
plenum with no openings or registers directly below furnace.
3. INSTALLATION CLEARANCES – As shipped from the factory,
each unit is approved for "zero inch" clearance. If additional
clearance is required, it will be indicated on the data label
attached to the furnace.
All manuals and user guides at all-guides.com
1½"
(38 mm)
RIGHT SIDE VIEW
1"
(25 mm)
WIRING KO'S
A
FILTER FRAME
B
(EITHER SIDE, REAR
C
OR BOTTOM)
18" x 18"
(457 mm x 457 mm)
1½" x 1½" KO
RETURN
(38 mm x 38 mm)
The safe and dependable operation of the furnace depends upon
proper installation and compliance with all national and local
codes and standards.
WIRING KO'S VALUES
A = 1" (25 mm)
B = 1/4" (6 mm) & 1¼" (32 mm)
C = 1/2" (13 mm) & 1½" (38 mm)
REAR VIEW
18" x 18"
(457 mm x 457 mm)
1½" x 1½" KO
RETURN
(38 mm x 38 mm)
4. TEMPERATURE RISE – Furnaces are shipped to operate at
0.20" (5 mm) W.C. (50 Pa) external static pressure. They are
certified for operation up to 0.50" (13 mm) W.C. (125 Pa). Check
the following page for temperature rise table on specification
chart and, if necessary, adjust the unit to match.
5. SERVICE CLEARANCE – Units are serviced from the FRONT.