GENERAL REQUIREMENTS AND SPECIFICATIONS
MODEL NO.
KW
21D10
10
21D15
15
21D18
18
21D20
20
21D23
22.5
21D25
25
21D27
27
*FACTORY SETTINGS.
SUBJECT TO CHANGE WITHOUT NOTICE.
OPERATING OPTIONS
The furnace is shipped from the factory in a "Standard Heating
Mode" (narrow switches in the Down position, wide switch in the
Middle — or Off — position). When the thermostat calls for heat,
the automatic controls will be activated and the furnace turns
"ON".
The blower will run at low speed or higher speed (as selected by
Speed Selector switch).
H
IGH
L
OW
S
S
PEED
ELECTOR
The Speed Selector switch is used to
control the fan speed. It is also used in
conjunction with the Continuous Speed
switch.
"Low" – The blower motor will operate at
low speed.
"High" – The blower motor will operate at
a higher speed.
All manuals and user guides at all-guides.com
240 VOLTS – SINGLE PHASE
BTUH
AMPS INCL. MOTOR
34120
46
51180
67
61420
77
68240
86
76842
94
85003
107
92130
116
10" x 8" (254 mm x 203 mm) BLOWER
SPEED
FLOW RATE
CFM
LOW**
L/s
CFM
MED-LOW
L/s
CFM
MED-HIGH
L/s
CFM
HIGH
L/s
WARNING:
**This speed can only be run with heater off, for cooling/ventilation purposes only.
During spring or fall, you may require less
rapid response when the thermostat calls
for heat.
When "Mild" is selected, it takes more time
to bring all the elements online.
When "Cold" is selected, the heating
elements come online faster.
(
'
)
CONT
D
HP
BLOWER
1/3
1/3
1/3
10" x 8"
(254 mm x 203 mm)
1/3
1/3
1/3
12" x 8"
3/4
(304 mm x 203 mm)
STATIC PRESSURE
(INCHES OF WATER COLUMN)
0.2
0.3
0.4
756
749
740
357
353
349
1035
1018
997
488
480
470
1177
1157
1132
556
546
534
1301
1276
1247
614
602
588
As the furnace heats up, it automatically switches to a medium
speed when additional elements are activated by the electronic
control, if it was initially set to run at low speed. The timing of this
blower speed change will depend on whether "Cold" or "Mild" is
selected on the Season Select switch.
You may, however, change from the Standard Heating Mode by
using the controls built into your furnace.
M
ILD
C
OLD
S
S
EASON
ELECT
3
TEMP. RISE @ 0.20 IN. W.C.
°C
°F
*SPEED
RPM
21
70
MED-LOW
814
24
25
MED-LOW
814
27
81
MED-LOW
814
33
91
MED-LOW
814
36
97
MED-LOW
814
37
99
MED-LOW
814
36
97
MED-HI
707
0.5
0.6
729
713
344
337
971
935
458
441
1102
1063
520
502
1207
1145
569
540
L
O
N
C
S
ONTINUOUS
PEED
When the "Low Heat" switch is selected
only one element will offer continuous
warmth.
When "No Heat" is selected the blower will
run continuously at either Low or High
speed as selected by the Speed Selector
switch.
When "OFF" is selected the blower is not
engaged.
H
OW
EAT
FF
H
O
EAT