Télécharger Imprimer la page

Mr. Heater Grand Teton Serie Mode D'emploi page 9

Masquer les pouces Voir aussi pour Grand Teton Serie:

Publicité

Les langues disponibles

Les langues disponibles

ADDITIONAL MOBILE HOME REQUIREMENTS
NOTE: Only approved for US mobile home, not
approved for mobile home in Canada.
All mobile home installations must be made in
accordance to Manufactured Home and Safety
Standard (HUD), CFR 3280, part 24.
PARTS & MATERIALS REQUIRED (NOT SUPPLIED)
WARNING: USE OF SINGLE WALL
CONNECTOR PIPE ANYWHERE IN MOBILE
HOME INSTALLATION IS NOT PERMITTED.
CAUTION: IT IS IMPORTANT TO USE ONLY
THE SPECIFIED COMPONENTS. USE OF
COMPONENTS OTHER THAN SPECIFIED
COMPONENTS MAY RESULT IN INCREASED
RISK TO YOU, YOUR STOVE, AND YOUR
HOME.
• #8 grounding wire.
• Two (2) National Electrical Code (NEC) approved
grounding device.
• A paint penetrating washer, such as a star washer.
All components of the ventilation system listed below
must be of the HT type and listed to UL 103 HT. Install
per chimney manufacturer's instructions.
• Double wall stove pipe having 6" (152mm) diameter
and made of either 24 MSG (minimum standard
gauge) black or 26 MSG blue steel.
• Ceiling thimble suitable for use in mobile home.
• Roof thimble suitable for use in mobile home.
• Spark arrestor suitable for use in mobile home.
• Roof flashing suitable for use in mobile home.
• Chimney cap which does not permit the entrance of
a 1/2" (13 mm) diameter rod.
• A factory-built chimney, minimum 15 ft (4.6m) tall
which conforms to ULC-S629, Standard for 650˚C
Factory-Built Chimneys.
ADDITIONAL INSTALLATION REQUIREMENTS
CAUTION: THE STRUCTURAL INTEGRITY OF
THE MOBILE HOME FLOOR, WALL, CEILING,
AND ROOF MUST BE MAINTAINED.
• The stove must be on installed on a level surface
which can support the weight of the stove.
• The stove must be bolted to the level surface so
that it permanently secured and can not be moved,
tipped, or have ventilation seals compromised.
• The stove must be grounded with #8 grounding
wire and terminated at each end with a National
Electrical Code (NEC) approved grounding device. A
paint penetrating washer such as a star washer shall
be installed where connected to steel frame of the
Mobile Home.
Wood Fire Stove
• The use of outside combustion air is mandatory
when installing this wood stove in a mobile or
manufactured home.
• The outside air connection pipe protrudes from
the bottom center of the stove; a kit (F500313)
is available from Enerco Group, Inc. designed for
connecting this unit to outside combustion air.
• If it is not feasible to use the F500313 outside air
hookup kit in your stove installation, other materials
may be used, provided the following rules are
followed:
— The duct must have a minimum diameter of 4
inches (10.2 cm).
— The duct must be made of metal exclusively,
not other materials such as plastic.
The end of this duct on the outside of the mobile
home must meet the following requirements:
— The duct hole must be equipped with a screen
which prevents rodents from infiltrating.
— The duct hole must be kept free of leaves,
snow, ice, or other debris that could restrict air
supply when the appliance is in operation.
• If the chimney exits the mobile home at any location
besides the roof and if that location is less than
7 feet (2.13 m) from the ground that the mobile
home is settled on, then the system must meet the
following requirements:
— A guard from the exit location up to a height of
7 feet (2.13 m) from the ground that the mobile
home is settled on.
Single-Wall
Figure 9
Mobile Home Installation Visual
E9