CLEARANCE TO COMBUSTIBLES
(Refer to Figure 1 and Table 1)
The following stated clearances represent the minimum
distances between the stove and any other object. No
objects should encroach into this space. This includes
but is not limited to carpet, furniture, children, pets,
clothing, fuel, or any other object. These clearances
may not be reduced by any means or regulatory
authority within United States or Canada.
The stove shall not be less than 17 inches (43.2 cm) (A)
from a side wall and 8.25 inches (21 cm) (B) from the
back wall. The wall of a vertical vent pipe must not be
less than 25 inches (63.5 cm) (C) from any wall.
The Minimum floor-to-ceiling distance of the room is
84 inches (213.4 cm).
The minimum distance between the ceiling and the
wall of any horizontal vent pipe is 18 inches (45.7 cm).
REAR WALL
G
G
E
A
C
USA
A 17 in. (43.2 cm)
B 8.25 in. (21 cm)
C 25 in. (63.5 cm)
D 14 in. (35.6 cm)
E 8 in. (20.3 cm)
F 16 in. (40.6 cm)
G 2 in. (5.1 cm)
H 6.5 in. (16.5 cm)
I
16 in. (40.6 cm)
Wood Fire Stove
FIGURE 1
E
FRONT OF STOVE
NON-COMBUSTIBLE
FLOOR PROTECTION
CANADA
17 in. (43.2 cm)
8.25 in. (21 cm)
25 in. (63.5 cm)
14 in. (35.6 cm)
8 in. (20.3 cm)
18 in. (45.7 cm)
2 in. (5.1 cm)
6.5 in. (16.5 cm)
16 in. (40.6 cm)
Table 1
CORNER INSTALLATION
The stove shall not be less than 6.5 inches (16.5 cm)
(H) from a corner. The wall of a vertical vent pipe
must not be less than 16 inches (40.6 cm) (I) from any
corner.
FLOORING SPACE (Refer to Figure 1 and Table 1)
The floor protector must extend at least [in U.S. - 16
in. (40.6 cm); in Canada - 18 in. (45.7 cm)] (F) to the
front and at least 8 in. (20.3 cm) (E) beyond each side
of the fuel loading and ash removal opening. The floor
protection must extend under the flue connector and
extend 2 in. (5.1 cm) (G) beyond each side of the pipe.
FLOORING MATERIAL
The stove may be installed on solid concrete or solid
masonry flooring. If the stove is to be installed on
combustible flooring, the floor must be protected with
non-insulated ember board.