Télécharger Imprimer la page

Delabie 510587 Manuel D'installation page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

OPERATION
• Opens and closes automatically by infrared presence detection of the hands.
• Before using for the first time, cancel the "sleep" mode (the pump rotates every 72 hours to avoid wear
of the silicone pipe): press the setting button d (Fig. B) for 2 seconds. The LED c (Fig. A) will light up for 3 seconds.
• To return the dispenser to the "sleep" mode: press the setting button d (Fig. B) 5 times in a row.
INSTALLATION
• Follow the instructions in Figs. C to G.
• Install the dispenser at least 250mm above the wash basin (350mm if the washbasin is made from stainless steel).
To avoid interference from infrared beams do not install a reflective object in the detection zone
of the sensor e (Fig. B) on the soap dispenser.
• Power supplied by 6 AA batteries - 1.5V (DC9V), supplied in the housing.
• Disconnect the cables f and g (Fig. H). Remove the lid a (Fig. A). Fill the reservoir (2) (Fig. A) with vegetable
based liquid soap, maximum viscosity 3,000 mPa.s.
• Replace the lid a (Fig. A) on the reservoir and reconnect the cables f and g (Fig. H). Follow the instructions
in Figs. I and J.
• Place hands beneath the sensor e (Fig. B) to operate the pump. Repeat until the soap begins to flow.
REMEMBER
• Our products must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Do not shake the soap dispenser.
• Do not block the soap outlet or the sensor.
ADJUSTMENT
Detection distance:
• Change to "setting" mode: press the setting button d (Fig. B) for 15 seconds. The LED c (Fig. A) will flash 5 times.
• Press the setting button d (Fig. B) again for 5 seconds: the LED c (Fig. A) will flash continuously.
• Place hands at the desired distance from the sensor e (Fig. B) (between 5 and 15cm) until the LED goes out.
Setting the detection distance is complete.
Dose size:
• Change to "adjust" mode: press the setting button d (Fig. B) for 15 seconds. The LED c (Fig. A) will flash 5 times.
• Press the setting button (4) (Fig. B) again twice: the LED c (Fig. A) will flash for 5 seconds.
• During these 5 seconds, place a hand beneath the sensor e (Fig. B): several doses (0.8ml default) will be dispensed
at the same time. Remove the hand when the desired dose is achieved. This new quantity will be dispensed with every
subsequent use.
SERVICING
The LED c (Fig. A) flashes continuously:
• Follow the instructions in Fig. C then disconnect the cables f and g (Fig. H). Unscrew the screws h then remove
the battery housing lid i (Fig. K). Change the 6 batteries (Fig. L).
• Replace the battery housing lid i and tighten the screws h (Fig. K).
MAINTENANCE & CLEANING
Do not use abrasive, chlorine or any other acid-based cleaning products.
Clean with mild soapy water using a cloth or a sponge.
Product conforms to current European Directives.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care and Technical Support:
The installation guide is available on: www.delabie.com
EN

Publicité

loading