1) Prepare parts to install.
Faceplate
2) Wrap pipe tape around threads of
adapter.
Install the adapter using 12mm hex
wrench, and if needed, an adjustable
wrench (for leverage).
Tighten until the screw holes in the
adapter are in the positions shown in
the image.
3) Confirm the distance from the
front of the adapter to the finished
wall surface.
The distance shall be 0 to 13/16"
(20mm). If the distance is not within
this range, adjust the supply line or
adapter to the correct position.
Installing the Bodyspray (TS100J1, J2)
Screws
Body Spray
Assembly
Set Screw
Screw Hole
Min 0"(0mm)
Max 13/16"(20mm)
Finished Wall
Surface
4
Adapter
Adapter
12mm
Hex Wrench