Slide the top unit of the mounting stand over the trace heater.
Slightly tighten the 4 fixing screws using a crosshead screwdriver.
Do not tighten them fully yet to allow the trace heater to be moved.
Remove 5 3/4" (145 mm) of the outer jacket on the end of the trace
heater.
21-59CZ-7D0001
6
7
Notice Technical data subject to change without notice.
No claims for damage arising from alternations, errors or misprints shall be allowed.
Push the grounding braid back. Use the screwdriver to form an
eyelet. Be careful not to damage the internal insulation jacket.
Bend the trace heater and pull the heating element out of the
grounding braid.
Twist the grounding braid in order to form a pigtail.
8
9
10
Page 5 / 25