Installation
Before mounting and removing the sensor, make sure that no
pressure is applied to the system. Horizontal mounting recom-
mended for high medium temperatures.
1. Screw the sensor into a G¾
process fitting.
2. Tighten the sensor with a
spanner until you can feel the
end stop.
The housing (A) is freely rotat-
able.
You can replace the Viton O-ring
(B) by the supplied EPDM O-ring.
The unit is adaptable for various G¾ process fittings (G¾ adapters
to be ordered separately as accessories).
Prozess adapter
Mount adapter (D) to the sensor
first, then sensor + adapter to
the process connection by means
of a nut, a clamping flange or
similar
If it is not possible to slide the fix-
ing element (C) down over the
top of the sensor: slide it up over
the bottom of the sensor before
the adapter is mounted.