Bedienungsanleitung
Operating instructions
Notice pour utilisateurs
R
Elektronischer
Drucksensor
Typ PN5
Electronic pressure
sensor
Type PN5
Capteur de pression
électronique
Forme PN5

Publicité

Table des Matières
loading

Sommaire des Matières pour IFM Electronic efector500 PN5

  • Page 1 All manuals and user guides at all-guides.com Bedienungsanleitung Operating instructions Notice pour utilisateurs Elektronischer Drucksensor Typ PN5 Electronic pressure sensor Type PN5 Capteur de pression électronique Forme PN5...
  • Page 2: Table Des Matières

    All manuals and user guides at all-guides.com Bedien- und Anzeigeelemente Mode/Enter [bar] Anzeige des Systemdrucks, LED-Display Anzeige der Parameter und Parameterwerte Anzeige des Schaltzustands; leuchtet, LED rot wenn der Ausgang durchgeschaltet ist Einstelltaste Anwahl der Parameter und Bestätigen der Mode / Enter Parameterwerte Einstellen der Parameterwerte Einstelltaste...
  • Page 3: Menü-Übersicht

    All manuals and user guides at all-guides.com Menü-Übersicht 70.0 Run Mode Anzeige des aktuellen Systemdrucks 5% - 6% - 7% - ... - 98% - 99% - 100% Schaltpunkt (SP1) 3% - 4% - 5% - ... - 97% - 98% - 99% Rückschaltpunkt (rP1) 0 - 0,2- ...- 9,8 - 10 - 11 - ...
  • Page 4: Bestimmungsgemäße Verwendung

    All manuals and user guides at all-guides.com 1. Bestimmungsgemäße Verwendung • Der Drucksensor erfaßt den Systemdruck, • zeigt durch ein LED-Display den aktuellen Systemdruck an, • und erzeugt ein Ausgangssignal entsprechend der eingestellten Schaltfunktion: Hysteresefunktion, Fensterfunktion, jeweils als Schließer oder Öffner. Einsatzbereich: Bestell- Zulässiger...
  • Page 5: Hysteresefunktion

    All manuals and user guides at all-guides.com Hysteresefunktion: Hysterese hält Schaltzustand des Ausgangs sta- bil, wenn der Systemdruck um den Sollwert schwankt. Hysterese Bei steigendem Systemdruck schaltet Ausgang Erreichen des Schaltpunkts (SP1); fällt der Systemdruck wieder ab, Schließer schaltet der Ausgang erst dann Öffner zurück, wenn der Rückschalt- punkt (rP1) erreicht ist.
  • Page 6: Betriebsmodi

    All manuals and user guides at all-guides.com 2. Betriebsmodi Das Gerät verfügt über folgende Betriebsmodi: Run-Modus (normaler Arbeitsbetrieb), Display-Modus (Anzeige der Parameter und der eingestellten Parameterwerte), Programmier- Modus (Einstellen der Parameterwerte). Run-Modus: Nach dem Einschalten der Versorgungsspannung befindet sich das Gerät im Run-Modus.
  • Page 7: Einstellbare Parameter

    All manuals and user guides at all-guides.com 3. Einstellbare Parameter (Menüstruktur: siehe Ausklappseite) Schaltpunkt: Oberer Grenzwert, bei dem der Ausgang seinen Schaltzustand ändert. • Einstellbar in Schritten von 1% des Meßbereichsendwerts. • Einstellbereich: 5 ... 100% des Meßbereichsendwerts. • Anzeige in bar. Rückschaltpunkt: Unterer Grenzwert, bei dem der Ausgang seinen Schaltzustand ändert.
  • Page 8: Montage

    All manuals and user guides at all-guides.com Ansprechzeit für den Schaltausgang; Dämpfung: Zeitspanne zwischen Änderung des Systemdrucks und Änderung des Schaltzustands. Es werden nur Druckänderungen > dAP aus- gewertet. Dadurch lassen sich Druckspitzen von kurzer Dauer oder hoher Frequenz ausfiltern. •...
  • Page 9: Programmieren

    All manuals and user guides at all-guides.com 6. Programmieren Führen Sie zum Programmieren die folgenden Schritte durch: Anwahl des Parameters, der verändert werden soll Drücken Sie die Taste “Mode/Enter” so oft, bis der gewünschte Parameter im Display erscheint. Anzeige des Parameters (hier SP1).
  • Page 10: Inbetriebnahme / Betrieb

    All manuals and user guides at all-guides.com 7. Inbetriebnahme / Betrieb Prüfen Sie nach Montage, elektrischem Anschluß und Programmie- rung, ob das Gerät sicher funktioniert. Störanzeigen während des Betriebs: = Überlastdruck (Systemdruck > 110% des max. Nenndrucks). (blinkend) = Kurzschluß im Schaltausgang; der Ausgang ist abgeschaltet.
  • Page 11: Technische Daten

    All manuals and user guides at all-guides.com 9. Technische Daten Betriebsspannung [V] ....... 18 ... 30 DC Strombelastbarkeit [mA] .
  • Page 12: Controls And Visual Indication

    All manuals and user guides at all-guides.com Controls and visual indication Mode/Enter [bar] display of the system pressure, LED display display of parameters and parameter values switching status; LED red lights if the output has switched Mode / Enter selection of the parameters and button acknowledgement of the parameter values setting of the parameter values...
  • Page 13: Menu Structure

    All manuals and user guides at all-guides.com Menu structure 70.0 Run Mode display of the current system pressure 5% - 6% - 7% - ... - 98% - 99% - 100% switch-on point (SP1) 3% - 4% - 5% - ... - 97% - 98% - 99% switch-off point (rP1) 0 - 0.2 - ...
  • Page 14: Function And Features

    All manuals and user guides at all-guides.com 1. Function and features • The pressure sensor detects the system pressure, • indicates the current system pressure by a 7 segment LED display, • and generates an output signal according to the set switch function: hysteresis function, window function, as N.O.
  • Page 15: Hysteresis

    All manuals and user guides at all-guides.com Hysteresis: The hysteresis keeps the switching state of the output stable if the system pressure varies about the preset value. When the system hysteresis pressure is rising, the output switches when the switch-on point has been reached (SP1);...
  • Page 16: Operating Modes

    All manuals and user guides at all-guides.com 2. Operating modes The unit has the following operating modes: Run mode (normal operating mode), display mode (indication of para- meters and the set parameter values), programming mode (setting of the parameter values). Run mode: When the supply voltage has been applied, the unit is in the Run mode.
  • Page 17: Adjustable Parameters

    All manuals and user guides at all-guides.com 3. Adjustable parameters (Menu structure: see fold out page) Switch-on point: Upper limit value at which the output changes its switching status. • adjustable in steps of 1% of the value of the measuring range •...
  • Page 18: Installation

    All manuals and user guides at all-guides.com Rise time for the switching output; damping: Time between the change in the system pressure and the change in the switching status. Only pressure changes > dAP are evalua- ted. Pressure peaks of short duration or high frequency can thus be filtered out.
  • Page 19: Programming

    All manuals and user guides at all-guides.com 6. Programming Take the following 3 steps for programming: Select the parameter to be changed Press the "Mode/Enter" button several times until the respective parameter is displayed. Indication of the parameter (here SP1). Set the parameter value Press the "Set"...
  • Page 20: Commissioning / Operation

    All manuals and user guides at all-guides.com 7. Commissioning / Operation After mounting, wiring and setting check whether the unit operates correctly. Faults displayed during operation: = overload pressure (system pressure > 110% of the max. nominal pressure) (flashing) = short-circuit in the switching output; the output is switched off 8.
  • Page 21: Technical Data

    All manuals and user guides at all-guides.com 9. Technical data Operating voltage [V] ....... 18 ... 30 DC Current rating [mA] .
  • Page 22: Eléments De Service Et D'indication

    All manuals and user guides at all-guides.com Eléments de service et d’indication Mode/Enter [bar] affichage visualisation de la pression du circuit, digital des paramètres et des valeurs de paramètre état de commutation; LED rouge allumée si la sortie a commuté bouton sélection des paramètres et Mode / Enter...
  • Page 23: Structure Du Menu

    All manuals and user guides at all-guides.com Structure du menu 70.0 Run Mode affichage de la pression actuelle 5% - 6% - 7% - ... - 98% - 99% - 100% point de consigne haut (SP1) 3% - 4% - 5% - ... - 97% - 98% - 99% point de consigne bas (rP1) 0 - 0,2 - ...
  • Page 24: Fonctionnement Et Caractéristiques

    All manuals and user guides at all-guides.com 1. Fonctionnement et caractéristiques • Le capteur de pression détecte la pression du circuit, • visualise la pression actuelle du circuit à l’aide d’un affichage digital, • génère un signal de sortie selon la fonction de commutation réglée: hystérésis, fonction fenêtre, respectivement normalement ouvert (N.
  • Page 25: Hystérésis

    All manuals and user guides at all-guides.com Hystérésis: L'hystérésis garantit un état de commutation stable en cas de fluctuations de la pression du cir- cuit autour de la valeur présélec- hystérésis tionnée. Si la pression du circuit augmente, la sortie commute lorsque la consigne haute est atteinte (SP1);...
  • Page 26: Modes De Fonctionnement

    All manuals and user guides at all-guides.com 2. Modes de fonctionnement Mode Run (mode de fonctionnement normal), mode Display (visuali- sation des paramètres et des valeurs du paramètre réglées), mode pro- grammation (réglage des valeurs du paramètre). Mode Run: Après la mise sous tension l'appareil se trouve en mode Run. Il surveille et commute la sortie transistor selon les paramètres réglés.
  • Page 27: Paramètres Réglables

    All manuals and user guides at all-guides.com 3. Paramètres réglables (Menu des fonctions: voir la page avec rabat) Point de consigne haut: Seuil auquel la sortie change son état de commutation • réglable en pas de 1% de la valeur de l'étendue de mesure •...
  • Page 28: Montage

    All manuals and user guides at all-guides.com Temps de réponse pour la sortie de commutation; amortissement: Temps entre le changement de la pression du circuit et le change- ment de l'état de commutation. Seulement les changements de pression > dAP sont évalués. Ainsi les pics de pression de courte durée ou de haute fréquence peuvent être filtrés.
  • Page 29: Programmation

    All manuals and user guides at all-guides.com 6. Programmation Pour effectuer la programmation procéder comme indiqué ci-dessous: Sélectionner le paramètre à changer Appuyer sur le bouton "Mode/Enter" plusieurs fois jusqu'à ce que le paramètre désiré soit affiché. Visualisation du paramètre (ici SP1).
  • Page 30: Mise En Service / Fonctionnement

    All manuals and user guides at all-guides.com 7. Mise en service / Fonctionnement Après le montage, le câblage et le réglage vérifier le bon fonctionne- ment de l'appareil. Signaux de défaut durant le fonctionnement: = surpression (pression du système > 110% de la pression nominale maxi) (clignotant) = court-circuit de la sortie de commutation;...
  • Page 31: Données Techniques

    All manuals and user guides at all-guides.com 9. Données techniques Tension d'alimentation [V] ......18 ... 30 DC Courant de sortie [mA] .
  • Page 32: Valeurs De Paramètre Réglées

    All manuals and user guides at all-guides.com Eingestellte Parameter-Werte Set parameter values Valeurs de paramètre réglées...
  • Page 33 Niederlassungen • Sales offices • Agences D ifm electronic gmbh vertrieb nord • 31135 Hildesheim • Tel. 0 51 21 / 76 67-0 ifm electronic gmbh vertrieb west • 45329 Essen • Tel. 02 01 / 3 64 75 -0 ifm electronic gmbh vertrieb mitte-west •...