Controls
NOTE
The control panel locates under the front side
cover. Remove the cover to access to its controls for
adjustment. (See page 3)
FUSE [30Ax3]
1 Fuse (0 A × )
NOTE
If you can't find the specified capacity fuse at your store etc., consult your
Kenwood dealer.
2 Battery terminal
3 Power control terminal
Controls the unit ON/OFF.
NOTE
Controls the unit power. Be sure to connect it with all the systems.
4 Ground terminal
5 Speaker output terminals
As this unit accepts speakers with a minimum impedance of 1 ohm, connect
speakers with 1-ohm or higher impedance to these terminals.
6 REMOTE terminal
Connects the Remote cable.
NOTE
Use the Remote cable of the optional accessory.
7 LINE IN terminal
8 LINE OUT terminal
The audio signal set with the LINE OUT FILTER switch will be output.
9 BOOST LEVEL (Bass boost level) control
Sets the level by which the low frequency range should be boosted.
0 Power indicator
- FREQUENCY (Bass boost frequency) control
Sets the center frequency around which the low frequency range should be
boosted.
= THERMAL MANAGEMENT indicator
Lights this indicator when the internal temperature is high.
~ PROTECTION indicator
Lights this indicator when the protection function is activated. (See page 2)
! Power indicator
When the power is turned on, the Power indicator lights.

English
Remote controller
( Optional accessory )
BATT.
GND
P.CON
SPEAKER OUTPUT
100
70
50
LPF
FREQUENCY[Hz]
THERMAL MANAGEMENT
PROTECTION
REMOTE
@ LPF(Low-Pass Filter) FREQUENCY control
This control adjusts the frequency band output from this unit.
# ISF (infrasonic filter) control
Ultralow frequencies that cannot be reproduced even by a subwoofer
speaker do not become sound but become unnecessary oscillations, which
affect the sound by causing distortion, etc. Setting this control cuts the
frequencies below the respective frequency.
This improves the reproduction performance of the speakers by eliminating
unnecessary oscillations which will not become sound.
$ INPUT SENSITIVITY control
Set this control according to the pre-output level of the center unit
connected with this unit.
NOTE
For the pre-output level, refer to the <Specifications> in the instruction
manual of the center unit.
% LINE OUT FILTER switch
Changing over the audio signal output to the LINE OUT terminal.
ON position:
The audio signal adjusted when setting LPF, INPUT SENSIVITY control and
Bass boost (optional accessory) is output to the LINE OUT terminal.
OFF position:
The audio signal input from the LINE IN terminal is output to the LINE OUT
terminal (through output).
CAUTION
The volume of the audio output to the LINE OUT terminal is different in ON
and OFF position. Remember this when changing the LINE OUT FILTER switch
from ON to OFF.
30
1
150
25
2
35
0.5
20
3
0.3
4
200
15
40
[MIN]
5
0.2
[MAX]
ISF
INPUT
FREQUENCY[Hz]
SENSITIVITY[V]
LINE OUT
FILTER
ON
OFF
L
R
LINE IN