3 CONNECTION INSTRUCTIONS
Refer to the instructions contained in the system manual for wiring, maximum distances and confi guration
operations.
3.1 CONNECTOR AND WIRING WITH CAT5 WIRE
Use Urmet RJ45 connector kit for connections (product on sale until stocks last).
Connect the CAT5 wire to one of the RJ45 connectors with Urmet logo:
Insert the wire in the guide respecting the colour coding shown (Standard T568B).
Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and
crimp the plug with a specifi c tool.
Make sure that the grey sheath remains inside the plug.
This type of connection DOES NOT ensure double insulation..
4 TECHNICAL SPECIFICATIONS
Power voltage and consumption on terminals V+ e V-
Power voltage: ............................................................................................................................... 44 – 57 Vdc
Max. consumption (video call) @48 V: .................................................................................................200 mA
Max. consumption (stand-by) @48 V: ....................................................................................................80 mA
Working temperature range: .................................................................................................. -10 °C ÷ +50 °C
Relay contact range C, NC, NO:
Maximum switching voltage: .................................................................................................................... 30 V
Maximum switching current: ...................................................................................................................3,5 A
Maximum switching load: ............................................................................................................. 40 VA 25 W
Garage gate relay contact range (SE2):
Maximum switching voltage: .................................................................................................................... 30 V
Maximum switching current: ...............................................................................................................200 mA
Max. distance from hall button: .............................................25 m with cable cross-section area 0.5 mm
Max. distance from open door sensor: .................................50 m with cable cross-section area 1.5 mm
Max. distance from supplementary power supply: .............100 m with cable cross-section area 1.5 mm
Max. distance from capacitance lock: ................................100 m with cable cross-section area 1.5 mm
Clean regularly with products suitable for metallic surfaces to keep the push-button panel looking
good in time. Do not use aggressive chemical products (e.g. solvents, ammonia, soda, etc.).
8
All manuals and user guides at all-guides.com
Wire
No.
1
2
1
3
4
8
~ 5 mm
1
8
Wire colour
White-Orange
Orange
White-Green
Blue
1
8
Wire
Wire colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Plug