MXE 12_15
20.10.2006
45
12:37 Uhr
Seite 45
english
6.6 Signalling
A two-color LED, red/green, is integrated for the signalling
of operational and error states
Designation on terminal box:
lights, flashes green
lights, flashes red
flashes alternately flashes green/red
Function
Pump OFF
Pump running in sector A
Pump running in sector B
Pump running in sector C
Speed limitation
Electronic fautes
Pump blocked
LED
Operation Fault
Contact
51-64
off
off
lit green
on
flashes green
on
irregularly**
flashes green
on
regularly*
flash
on
green/red
flash red
regularly
off
lit red
off
* = flashing regularly:
1 s on/ 1 s off
** = flashing irregularly:
1.5 s on/ 0.5 s off/ 0.5 s on/ 0.5 s off
1)
= after 2 min.
Contact
51-54
off
off
off
off
off
on
on
1)
1)