MXE 12_15
20.10.2006
42
MXE 12, MXE 13
Fitting:
– Remove existing cover
– Connect operating
and fault message
– 51, 54: fault message
– 51, 64: operating message
Potential-free closing
contact max. 250 V, 1 A
– Insert plug in base p.c.b.,
note position (marked red)
– Fit cable screw connector
– Fit cover carefully
MXE 14, MXE 15
Fitting:
– Remove existing cover
– Connect analogue module
(71, 72)
– Insert analogue module
in base p.c.b
– Fit cover carefully
Notes:
If the analogue modul
is connected, the rotary
button on the terminal box
(pressure setting) has
no function.
If the analogue module
is not connected to terminals
71, 72, the pump operates
at minimum power
(no voltage corresponds
to 0 volt).
12:37 Uhr
Seite 42
english
5.5 Option: operating and fault message for MXE 12, MXE 13
5.6 Option: analogue module for MXE 14, MXE 15
Analogue input 0..10 V/ 0..20 mA for external input of speed
0 – 20 mA
0 – 10 Volt
Delivery
condition
Before removing the terminal box cover and before
any dismantling of the pump, do not fail to switch
off the entire power supply.
red