3.1
Assembling the control unit
The control unit can be opened only when the main switch <14> is in the OFF position.
• Turn the main switch <14> to the OFF position, and fold the housing open.
• Assemble the housing at the intended location, using all four fastening options in the corners. A drilling
template is included in the delivery scope.
3.2
Connecting the wastewater pump(s)
Connect the wastewater pump(s) as follows:
• Route the connecting cables through the housing apertures as
far as the connecting terminals.
• Set up the connections according to the connection plan (in the
housing cover of the control unit).
Explanation of the connections <27>
- 1 to 3 Phases
- 4 + 5 Coil temperature switch
- 5 + 6 Temperature fuse*
- PE (protective earth conductor)
* Provided for the use of ATEX pumps.
The illustration shows an excerpt of the connection plan located in
the housing cover.
V 1.3
All manuals and user guides at all-guides.com
3 Assembly
37 / 160
3 Assembly
[5]
[6]