Compatible transmitters
3
1
2
Transmitters range :
- 1, 3,4 & 5 : 20 m through 2 concrete walls .
- 2 : 40 m m through 2 concrete walls.
Location of the "PROG" key on Hz transmitters >
- 12 transmitters max. / 3 EOSUN Hz VS sensors max. for one motor.
- Do not position the transmitter near metal in order to avoid range losses.
End limits adjustment
4
4.1 - Learning mode
- Switch ON the motor.
- Simultaneously press the UP and DOWN keys of a Hz
transmitter. The motor will run for 0,5 second in one direc-
tion, then in the other.
The transmitter now controls the ESP Hz motor in
unstable mode, move to stage 4.2.
4.2 - Checking the rotation direction
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction , move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the STOP key
for at least 3 seconds. The motor will confirm the reversal of the rotation direction by running for 0,5 second
in one direction, then in the other direction. Go to step 4.3.
a
>>
b
4.3 - Adjustement of the down end limit
- With the T5ESPHz / T6ESPHz motor, there is no adjustment of the up end limit.
1
1- Move the motor to the wished DOWN end limit position using the "DOWN" and "UP" keys.
2- To memorize the DOWN end limit position, press simultaneously the "STOP" and "UP" keys. The motor will
run automatically in the "UP" direction.
3- Before the motor reaches the UP end limit, press the "STOP" key.
4- Press 2s on the "stop" key to confirm the adjustments. The motor will stop and will run for 0,5 second in
one direction and then in the other. Go to step 5.
- If you do not want to use this transmitter as the individual control:
- Switch the power supply off (2 seconds minimum).
- repeat the opération 4.1* with a new transmitter and then go to step §5.
* In this case, the motor will run for half a second in both directions, that means the limits setting is already
done
All manuals and user guides at all-guides.com
3
4
OK
>>
>>
>>
2
1 : Wall Hz transmitter
2 : Long-range Hz transmitter
3 : 1/5 channels Hz / EOSUN Hz transmitters
4 : Hz timer
5 : EOSUN Hz VS
5
1
PROG
4.3
>>
3s
3
2
3
4
PROG
PROG
>>
ON
>>
4
5
PROG
OK
4.3
>>
2s
2 / 4

Publicité

loading

Ce manuel est également adapté pour:

T6e sp hz