Pro-Pac system
Pro-Pac 30/45/70/90/140M/MY
Owner installation manual (SD566252 issue 51)
page 1
SD566252 ISSUE 48

Publicité

loading

Sommaire des Matières pour Calorex Pro-Pac 30M

  • Page 1 All manuals and user guides at all-guides.com Pro-Pac system Pro-Pac 30/45/70/90/140M/MY Owner installation manual (SD566252 issue 51) page 1 SD566252 ISSUE 48...
  • Page 2 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL SD566252 ISSUE 51...
  • Page 3 All manuals and user guides at all-guides.com HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment, ONLY competent persons should carry out any work on this type of machine. (SEE GUARANTEE) CONTENTS AIR/WATER HEAT PUMPS ............4 THE HEAT PUMP CYCLE ............5 INSTALLATION.
  • Page 4 The units are fully packaged and should be sited outside in a well ventilated area. The Calorex Pro-Pac range of air/water heat pumps for swimming pool applications consist of 5 models. Heat pumps Other features include integral safety devices to protect the on this manual are designed for heating pool water and heat pump from internal and external faults.
  • Page 5 1. THE EVAPORATOR collects the heat from the outside 2. THE COMPRESSOR where it is compressed and ambient air, pre-heated by the sun. In the Calorex swimming upgraded to a much higher temperature. The hot vapour pool heat pumps, high volumes of outside air are drawn into now enters –...
  • Page 6 (see installation drawings). Ensure heat pump on site is as ordered, i.e. model, electrical supply and All Calorex heat pumps are by design as quiet as is practical, however factory fitted options. due consideration should be given to siting in order to fully exploit Inspect unit for damage, in particular inspect the evaporator (finned this feature, i.e.
  • Page 7 All manuals and user guides at all-guides.com 2. AIR FLOW Due consideration must be given to air flow, ie do not obstruct inlet or outlet and ensure discharge air cannot recirculate to inlet (see figures 1 and 2) FIGURE 2 FIGURE 1 TYPICAL OUTSIDE INSTALLATION TYPICAL INSIDE OR PLANT ROOM INSTALLATION...
  • Page 8 1½" domestic waste piping. In this case it is necessary to ensure that the Calorex Heat Pump is placed on a level plinth so that the condensate can run away with adequate fall to waste ie ½"...
  • Page 9 All manuals and user guides at all-guides.com IMPORTANT All pool purifying devices and chemical injection systems to be fitted down stream of heat pumps unless installation is as per filter dosing (see figure 3). This includes the practice of dosing chemicals direct into skimmer basket, which results in concentrated corrosive liquids passing over vulnerable metal components.
  • Page 10 POOL WATER SCHEMATIC (STANDARD) ENSURE POOL FILTRATION PUMP SELECTION ALLOWS FOR ALL SYSTEM RESISTANCE POOL SANITISER OR CHEMICAL DOSING POSITION AFTER CALOREX HEATER IF FITTED CALOREX FLOW FLOW SETTING SETTING PRESSURE GAUGES...
  • Page 11 All manuals and user guides at all-guides.com 5.0 ELECTROLYTIC CORROSION IN SWIMMING POOLS Electrolytic corrosion will occur when dissimilar metals that are in contact with each other create a potential difference between themselves. Sometimes separated by a conductive substance known as an electrolyte, the dissimilar metals will create a small voltage (potential difference) that allows the ions of one material to pass to the other.
  • Page 12 30mA trip separate from any other associated equipment. Inconsistent electrical supply The following limits of operation must not be exceeded if Calorex machines are to be guaranteed either in performance or warranty terms: Voltage...
  • Page 13 All units have interlock circuit incorporated in control circuit, brought out Fig. 5 to two terminals. These terminals are shorted out for factory testing. RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP WITH SINGLE The interlock may be used to control the heat pump from a remote PHASE WATER PUMP location or a built in flow switch.
  • Page 14 All manuals and user guides at all-guides.com MAINS SUPPLY IN PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Fig. 5 RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP WITH SINGLE PHASE WATER PUMP SWITCHED FUSE ISOLATOR WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH...
  • Page 15 All manuals and user guides at all-guides.com Pro-Pac 30BM THREE PHASE 400V 3 N~ 50Hz ELECTRICAL CIRCUIT DIAGRAMS FAN CIRCUIT BREAKER TRIP / OFF = BREAK CONTACT CONTACTOR 6 (N/C) 6 (N/O) 4 (N/C) 4 (N/O) 2 (N/C) 2 (N/O) COMP CIRCUIT BREAKER MCB SETTINGS TRIP / OFF = BREAK CONTACT...
  • Page 16 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Pro-Pac 45BM THREE PHASE (400V 3 N~ 50Hz) FAN CIRCUIT BREAKER TRIP / OFF = BREAK CONTACT CONTACTOR 6 (N/C) 6 (N/O) MCB SETTINGS 4 (N/C) 4 (N/O) 2 (N/C) 2 (N/O) CONTROL...
  • Page 17 All manuals and user guides at all-guides.com Pro-Pac 45EM THREE PHASE (220V 3~ 60Hz) FAN CIRCUIT BREAKER TRIP / OFF = BREAK CONTACT CONTACTOR 6 (N/C) 6 NO 4 (N/C) 4 NO 2 (N/C) 2 NO MCB SETTINGS COMP CIRCUIT BREAKER TRIP / OFF = BREAK CONTACT CONTROL COMPRESSOR...
  • Page 18 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Pro-Pac 70BM THREE PHASE (400V 3N~ 50Hz) CIRCUIT BREAKER TRIP / OFF = BREAK CONTACT CONTACTOR 6 (N/O) 6 (N/C) 4 (N/C) 4 (N/O) MCB SETTINGS 2 (N/C) 2 (N/O) CONTROL COMPRESSOR...
  • Page 19 All manuals and user guides at all-guides.com Pro-Pac 90BM THREE PHASE (400V 3 N~ 50Hz) L1 L2 L3 MAINS LIGHT MCB SETTINGS CONTROL COMPRESSORS FANS 2.5A 23.8A 1.1A MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT MAXIMUM RATE 12 (N/C)
  • Page 20 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Pro-Pac 140BM THREE PHASE (400V 3 N~ 50Hz) MAINS LIGHT MCB SETTINGS CONTROL COMPRESSORS 1 & 2 FANS 1 & 2 30.7A 2.2A 2.5A WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED...
  • Page 21 All manuals and user guides at all-guides.com Pro-Pac 30BMY THREE PHASE (400V 3 N~ 50Hz) COMP SOFT START COMPRESSOR CIRCUIT BREAKER IF FITTED CONTACTOR TRIP / OFF = BREAK CONTACT 6 (N/O) (W1) 6 (N/C) 4 (N/C) 4 (N/O) (V1) COMPRESSOR MCB SETTINGS 2 (N/C)
  • Page 22 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Pro-Pac 45BMY THREE PHASE (400V 3 N~ 50Hz) COMP COMPRESSOR CIRCUIT BREAKER CONTACTOR TRIP / OFF = BREAK CONTACT MCB SETTINGS 6 (N/C) 6 (N/O) (W1) CONTROL COMPRESSOR 2.5A 23.8A 1.1A...
  • Page 23 All manuals and user guides at all-guides.com Pro-Pac 45EMY THREE PHASE (220V 3 ~ 60Hz) COMP CIRCUIT BREAKER CONTACTOR TRIP / OFF = BREAK CONTACT 6 (N/C) 6 (N/O) (W1) MCB SETTINGS COMPRESSOR CONTROL 4 (N/C) 4 (N/O) (V1) COMP 2.5A 46.8A 3.3A...
  • Page 24 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Pro-Pac 70BMY THREE PHASE (400V 3 N~ 50Hz) SOFT START COMPRESSOR COMPRESSOR IF FITTED CIRCUIT BREAKER CONTACTOR 6 (N/C) 6 (N/O) (W1) 4 (N/C) 4 (N/O) (V1) COMPRESSOR 2 (N/C) 2 (N/O) (U1)
  • Page 25 All manuals and user guides at all-guides.com Pro-Pac 90BMY THREE PHASE (400V 3 N~ 50Hz) MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY MCB SETTINGS SWITCHED TO THE ON CONDITION WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT MAXIMUM RATE CONTROL COMPRESSORS FANS...
  • Page 26 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL Pro-Pac 140BMY THREE PHASE (400V 3 N~ 50Hz) PHASE ROTATION CONTROL CIRCUIT BREAKER RELAY TRIP / OFF = BREAK CONTACT (N/C) 2 (N/C) 4 (COM) 11 (N) 2 1 (L) (N/O) 14 (N/C) 6...
  • Page 27 All manuals and user guides at all-guides.com 6.0 REGULAR PLANNED MAINTENANCE Operations to be carried out during a regular planned maintenance visit are as follows: Replace all belts where fitted. Clean or replace filters as applicable. (This action may be required more frequently than regular servicing.
  • Page 28 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL 7.0 CONTROLS AND INDICATION LAMPS THERMOSTAT Adjustable single stage digital thermostat controls and maintains heating level. Press and release ‘P’ key to display required temperature, to alter required temperature press up or down symbols.
  • Page 29 All manuals and user guides at all-guides.com NOT USED INCREASE SET POINT DECREASE SET POINT ACCESS SET POINT STANDBY SWITCH GREEN CLEAR AMBER AMBER AMBER PP90/140 M MAINS IN DEFROST WATER FLOW OK GENERAL FAULT FAULT, FRIDGE CIRCUIT 1 FAULT, FRIDGE CIRCUIT 2 SD566252 ISSUE 51...
  • Page 30 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL 8.0 HEAT PUMP MALFUNCTION WARNING: Isolate machine electrically before entering machine or removing The refrigeration circuit can only be worked on by an authorised/competent panels. technician in accordance with EU 517/2014. Any sign of abnormal operation such as water dripping should be reported The user check list should be carried out before initiating a service call.
  • Page 31 All manuals and user guides at all-guides.com USER CHECK LIST 90/140BM LAMP ACTION UNIT DOES NOT OPERATE MAINS FAULT AMBER FRIDGE FAULT AMBER Check mains supply, -external fuses - isolator etc. 1 AND/OR 2 DEFROST WHITE WATERFLOW GREEN MAINS Water flow inadequate FAULT AMBER Check water pump to restore flow through machine.
  • Page 32 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL LAMP ACTION UNIT DOES NOT OPERATE MAINS FAULT AMBER FRIDGE FAULT AMBER Check thermal motor starters for fans have not tripped. Check soft start has not 1 AND/OR 2 tripped (if fitted).
  • Page 33 All manuals and user guides at all-guides.com 9.0 DATA SHEETS AIR TO WATER HEAT PUMPS FOR SWIMMING POOL AND HOT WATER APPLICATIONS. 400V 3N~ 50HZ UNITS (BM) model Pro-Pac 30 Pro-Pac 45 Pro-Pac 70 Pro-Pac 90 Pro-Pac 140 UNITS DUTY Air On @ 20°C, 65%RH HEATING Output To Water (@ 26ºC)
  • Page 34 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL AIR TO WATER HEAT PUMPS FOR SWIMMING POOL AND HOT WATER APPLICATIONS. 220V 3~ 60HZ UNITS (EM) model:- Pro-Pac 30 Pro-Pac 45 Pro-Pac 70 Pro-Pac 90 Pro-Pac 140 UNITS DUTY Air On @ 20°C, 65%RH...
  • Page 35 All manuals and user guides at all-guides.com AIR TO WATER HEAT PUMPS FOR SWIMMING POOL AND HOT WATER APPLICATIONS. 400V 3N~ 50HZ UNITS (BMY) model Pro-Pac 30 Pro-Pac 45 Pro-Pac 70 Pro-Pac 90 Pro-Pac 140 UNITS DUTY Air On @ 20°C, 65%RH HEATING Output To Water (@ 26ºC) Electrical Input...
  • Page 36 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL AIR TO WATER HEAT PUMPS FOR SWIMMING POOL AND HOT WATER APPLICATIONS. 220V 3~ 60HZ UNITS (EMY) model Pro-Pac 30 Pro-Pac 45 Pro-Pac 70 Pro-Pac 90 Pro-Pac 140 UNITS DUTY Air On @ 20°C, 65%RH...
  • Page 37 All manuals and user guides at all-guides.com 10.0 INSTALLATION DRAWINGS SD566252 ISSUE 51...
  • Page 38 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL SD566252 ISSUE 51...
  • Page 39 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 40 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL SD566252 ISSUE 51...
  • Page 41 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 42 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL SD566252 ISSUE 51...
  • Page 43 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 44 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL SD566252 ISSUE 51...
  • Page 45 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 46 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL SD566252 ISSUE 51...
  • Page 47 All manuals and user guides at all-guides.com 11.0 WINTERISATION PROCEDURE WARNING Isolate machine before opening! As heat pump embodies electrical and rotational equipment, it is recommended for your own safety that a competent person carries out the following procedure. Drain Down Procedure Flush through water circuit in heat pump by using CLEAN TAP WATER (NOT POOL WATER) via hose into outlet connection –...
  • Page 48 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL 12.0 WARRANTY CONDITIONS The following exclusions apply to the Warranty given by Dantherm Ltd. No If in doubt or if advice is required please contact the Dantherm Group UK Service Department by calling 01621 856611 (option 4) or emailing claims will be accepted if : service.department@dantherm.com...
  • Page 49 All manuals and user guides at all-guides.com 13.0 REFRIGERATION DIAGRAMS PROPAC M FRIDGE CIRCUIT NOTE PROPAC 90/140 USES 2 FRIDGE CIRCUITS. NOTES DENOTES INSULATION PROCESS PORT DRIER 70/140 LIQUID SOLENOID INDICATOR VALVE DRIER RECEIVER WATER CONDENSERS SERVICE SERVICE EVAPORATOR SCHRADER SCHRADER 150.00 COMPRESSOR...
  • Page 50 All manuals and user guides at all-guides.com PR0-PAC SYSTEM OWNER INSTALLATION MANUAL PROPAC MY FRIDGE CIRCUIT NOTE PROPAC 90/140 USES 2 FRIDGE CIRCUITS. DENOTES INSULATION CAPILLARY PROCESS PORT DEFROST SOLENOID LIQUID DRIP TRAY PROBE VALVE INDICATOR HEATER DRIER RECEIVER DRIER EVAPORATOR 70/140 WATER...
  • Page 51 All manuals and user guides at all-guides.com 14.0 MACHINE RECORD LOG In order to comply with European F-Gas regulations, it is necessary for hermetically sealed systems with more than 6kg refrigerant to be leak tested annually. The operator of the unit is responsible for seeing that the test is carried out. For machines affected (See DATA SHEET on pages 32 and 33) A sample log sheet can be seen below.
  • Page 52 All manuals and user guides at all-guides.com danthermgroup.com Dantherm Ltd. Unit 12, Galliford Road Maldon CM9 4XD United Kingdom Calorex is part of the +44 (0)1621 856611 sales.uk@dantherm.com SD566252 ISSUE 51...
  • Page 53 All manuals and user guides at all-guides.com Pro-Pac system Pro-Pac 30/ 45/ 70/ 90/ 140M/MY Manuel d’Installation (SD566252 issue 51) Pour les piscines extérieures et intérieures page 1 SD566252 ISSUE 49...
  • Page 54 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION SD566252 ISSUE 51...
  • Page 55 All manuals and user guides at all-guides.com MISE EN GARDE D’HYGIENE ET DE SECURITE Comme le déshumidificateu contient des éléments électrique et tournants, le interventions sur ce type de machine ne peuvent être faites QUE par un personnel compétent. (VOIR LA GARANTIE) TABLE DES MATIERES MODELES PROPAC 30/45/70/90/140BM ET BMY ....4 INSTALLATION ................6...
  • Page 56 (avec une utilisation à l’année) et fonctionnent dans une plage de température ambiante variant de -15ºC à 40ºC. NOTE IMPORTANTE Dantherm Ltd. est certifié par la chartre de qualité, ISO 9001:2000. Toutes les Pompes à Chaleur Calorex sont aux normes Européennes CE. SD566252 ISSUE 51...
  • Page 57 La vapeur chaude pénètre par le soleil. Dans les pompes à chaleur pour piscine Calorex, un ou alors dans: plusieurs ventilateurs brassent des débits importants d’air extérieur à...
  • Page 58 (voir les plans d’installation). Inspectez la machine pour vérifier qu’elle n’a pas été Toutes les pompes à chaleur Calorex ont été conçues pour endommagée, en particulier l’évaporateur (côté ailettes) pour vérifier être les plus silencieuses possibles; cependant, on doit tenir compte du qu’il est en bon état.
  • Page 59 All manuals and user guides at all-guides.com 2. CIRCULATION DE L’AIR On doit tenir compte de la circulation de l’air ainsi; on ne doit pas obstruer les entrées et les sorties, et on doit s’assurer que l’air refoulé ne peut pas être recirculé. (Voir figures 1 et 2) FIGURE 1 FIGURE 2 INSTALLATION TYPIQUE A L' EXTERIEUR...
  • Page 60 Celui-ci devra être raccordé à une tuyauterie 1½” pouce. Dans ce cas, on devra donc vérifier que la Pompe à Chaleur Calorex est de niveau pour que les condensats puissent s’écouler librement et ne pas déborder par dessus les bords du bac à...
  • Page 61 All manuals and user guides at all-guides.com IMPORTANT Tous les systèmes de purification d’eau et d’injection de produits chimiques doivent être installés en aval de la pompe à chaleur, (sur la sortie d’eau de la PAC), sauf s’il s’agit d’une installation d’injection avec filtre (voir la figure 3).
  • Page 62 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION 4. DETERMINATION DU DEBIT D’EAU Les modèles Pro-Pac sont équipés d’un contrôleur de débit d’eau qui empêche tout démarrage de la pompe à chaleur si le débit d’eau est inférieur au débit minimum nécessaire. Augmenter progressivement le débit passant par la pompe jusqu’à...
  • Page 63 All manuals and user guides at all-guides.com 5.0 CORROSION ELECTROLITIQUE EN PISCINE La corrosion électrolytique se produit lorsque des métaux dissemblables en contact les uns avec les autres créent une différence de potentiel entre eux. Parfois séparés par une substance conductrice connue sous le nom d’électrolyte, les métaux dissemblables vont créer une légère tension (différence de potentiel) qui permettra aux ions d’un matériau de passer vers l’autre.
  • Page 64 à la fuite de courant vers la terre (30 mA) sur tous les circuits électriques de la piscine. SPÉCIFICATIONS DE L’ALIMENTATION ELECTRIQUE On ne doit pas dépasser les limites suivantes pour obtenir les performances spécifiées et pour bénéficier de la garantie Calorex : Tension Minimum Maximum Machines triphasées (EU)
  • Page 65 (voir les figures 5 et 6). Fig. 5 INSTALLATION ELECTRIQUE RECOMMANDEE POUR LA POMPE A CHALEUR Fig. 5 CALOREX AVEC UNE POMPE A EAU MONOPHASEE INSTALLATION ELECTRIQUE RECOMMANDEE POUR LA POMPE A CHALEUR SECTIONNEUR AVEC FUSIBLE A CALOREX AVEC UNE POMPE A EAU MONOPHASEE...
  • Page 66 ALOREX AVEC UNE POMPE A EAU TRIPHASEE SECTIONNEUR AVEC FUSIBLE A MOINS DE 2 m DE LA POMPE A CHALEUR ET DE CAPACITE CONFORME A LA FICHE TECHNIQUE POMPE A CHALEUR CALOREX TRIPHASEE ALIMENTATION POMPE A EAU TRIPHASEE L1 L2 L3 L3 L2...
  • Page 67 All manuals and user guides at all-guides.com SCHEMAS ELECTRIQUES PROPAC 30BM TRIPHASEE (400V ~3N 50Hz) DISJONCTEUR CONTACTEUR VENTILATEUR 6 (N/F) 6 (N/O) 4 (N/F) 4 (N/O) VENTILATEUR 2 (N/F) 2 (N/O) VALEURS DISJONCTEUR CIRCUIT DISJONCTEUR COMPRESSEUR VENTILATEUR ELECTRIQUE COMPRESSEUR CONTACTEUR 6 (N/F) (W1) 6 (N/O)
  • Page 68 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PROPAC 45BM TRIPHASEE (400V~ 3 N) 50Hz DISJONCTEUR VENTILATEUR CONTACTEUR 6 (N/F) VALEUR DISJONCTEUR 6 (N/O) 4 (N/F) CIRCUIT 4 (N/O) COMPRESSEUR VENTILATEUR VENTILATEUR ELECTRIQUE 2 (N/F) 2 (N/O) 2.5A 23.8A 1.1A...
  • Page 69 All manuals and user guides at all-guides.com PROPAC 45EM TRIPHASEE (220V 3~ 60Hz) DISJONCTEUR VENTILATEUR CONTACTEUR 6 (N/F) 6 NO 4 (N/F) 4 NO VENTILATEUR 2 (N/F) 2 NO DISJONCTEUR COMPRESSEUR CONTACTEUR 6 (N/F) (W1) 6 (N/O) 4 (N/F) (V1) 4 (N/O) COMP VALEUR DISJONCTEUR...
  • Page 70 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PROPAC 70BM TRIPHASEE (400V ~ 3 N 50Hz) DISJONCTEUR VENTILATEUR VALEUR DISJONCTEUR CONTACTEUR VENTILATEUR CIRCUIT COMPRESSEUR VENTILATEUR 6 (N/O) 6 (N/F) ELECTRIQUE 4 (N/O) 4 (N/F) 2.5A 36.8A 2.7A 2 (N/O) 2 (N/F) DISJONCTEUR...
  • Page 71 All manuals and user guides at all-guides.com PROPAC 90BM TRIPHASEE (400V ~ 3 N 50Hz) NEUTRE VOYANT ALIMENTATION VALEUR DISJONCTEUR CIRCUIT COMPRESSEUR 1 ET 2 VENTILATEUR 1 ET 2 ELECTRIQUE 2.5A 23.8A 1.7A 12 (N/F) (N) 2 1 (L) BORNES D'ALIMENTATION BORNES HORLOGE...
  • Page 72 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PROPAC 140BM TRIPHASEE (400V ~ 3 N 50Hz) NEUTRE VOYANT ALIMENTATION VALEUR DISJONCTEUR CIRCUIT COMPRESSEUR 1&2 VENTILATEUR 1&2 ELECTRIQUE 30.7A 2.6A 2.5A 12 (N/F) (N) 2 1 (L) BORNES BORNES D'ALIMENTATION D'ASSERVISSEMENT...
  • Page 73 All manuals and user guides at all-guides.com PROPAC 30BMY TRIPHASEE (400V ~ 3 N 50Hz) DISJONCTEUR DEMARRAGE AMORTI CONTACTEUR COMPRESSEUR SI INSTALLE COMPRESSEUR 6 (N/F) 6 (N/O) (W1) 4 (N/O) (V1) 4 (N/F) COMP 2 (N/O) (U1) 2 (N/F) VALEURS DISJONCTEUR 22 (N/F) TEMPORISATION RECHAUFFEUR...
  • Page 74 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PROPAC 45BMY TRIPHASEE (400V ~ 3 N 50Hz) CONTACTEUR DISJONCTEUR COMPRESSEUR 6 (N/F) 6 (N/F) (W1) 4 (N/F) 4 (N/F) (V1) COMP VALEURS DISJONCTEUR 2 (N/F) 2 (N/F) (U1) CIRCUIT COMPRESSEUR VENTILATEUR...
  • Page 75 All manuals and user guides at all-guides.com PROPAC 45EMY TRIPHASEE (220V 3~ 60Hz) DISJONCTEUR CONTACTEUR COMPRESSEUR 6 (N/F) 6 (N/O) (W1) 4 (N/F) 4 (N/O) (V1) COMP 2 (N/F) 2 (N/O) (U1) 22 (N/F) TEMPORISATION 1 RECHAUFFEUR (12 HEURES) COMPRESSEUR VALEURS DISJONCTEUR RELAIS (R2) CIRCUIT...
  • Page 76 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PP70BMY TRIPHASEE (400V ~ 3 N 50Hz) CONTACTEUR DISJONCTEUR COMPRESSEUR COMPRESSEUR 6 (N/F) 6 (N/O) (W1) 4 (N/F) 4 (N/O) (V1) COMP 2 (N/F) 2 (N/O) (U1) 22 (N/F) RECHAUFFEUR COMPRESSEUR RELAIS (R2)
  • Page 77 All manuals and user guides at all-guides.com PP90BMY TRIPHASEE (400V ~ 3 N 50Hz) NEUTRE L1 L2 L3 VOYANT ALIMENTATION MONITEUR DE PHASES DISJONCTEUR CIRCUIT ELECTRIQUE TRIP / OFF = BREAK CONTACT (N/F) 2 (COM) 11 (N/F) 4 (N) 2 1 (L) (N/O) 14 (N/F) 6...
  • Page 78 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PROPAC 140BMY TRIPHASEE (400V ~ 3 N 50Hz) NEUTRE L1 L2 L3 VOYANT ALIMENTATION DISJONCTEUR CIRCUIT ELECTRIQUE MONITEUR TRIP / OFF = BREAK CONTACT DE PHASES (N/F) 2 (COM) 11 (N/F) 4 (N/O) 14 (N) 2...
  • Page 79 All manuals and user guides at all-guides.com VÉRIFICATION ET MAINTENANCE Des opérations de maintenance régulières doivent être effectuées comme suit : Remplacement des courroies. Nettoyer ou remplacer les filtres si nécessaire (Cette vérification s’effectuera plus fréquemment que les autres opérations régulières).
  • Page 80 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION COMMANDES ET VOYANTS THERMOSTAT Le thermostat digital ajustable contrôle et maintien le niveau de chauffage. Ajustement de la température désirée: Cliquez sur ‘P’ pour afflicher la température désirée. Pour modifier cette valeur, appuyer sur les touches vers le ‘haut’...
  • Page 81 All manuals and user guides at all-guides.com NON UTILISE AUGMENTATION DU POINT DE CONSIGNE BAISSE DU POINT DE CONSIGNE ACCES AU POINT DE CONSIGNE COMMUTATEUR MARCHE/VEILLE ROUGE VERT BLANC ORANGE ORANGE ORANGE ALIMENTATION PRINCIPALE DEFAUT CIRCUIT FRIGORIFIQUE 2 DEFAUT DEGIVRAGE DEFAUT CIRCUIT FRIGORIFIQUE 1 DEBIT D'EAU COMMANDE SUR LES MODELES PROPAC 90/140...
  • Page 82 ATTENTION-DANGER: Coupez l’alimentation électrique de la Si vous avez des doutes ou besoin de conseils, contactez le machine avant de pénétrer dans la machine ou de déposer les service après vente de Calorex chez votre distributeur. panneaux. Tout signe de disfonctionnement de la machine devra On doit effectuer les vérifications suivantes avant d’appeler le...
  • Page 83 All manuals and user guides at all-guides.com LISTE DE VERIFICATIONS MODELES PROPAC 90/140 BM VOYANT ACTION LA MACHINE NE FONCTIONNE PAS ALIM PRINCIPALE ROUGE DEFAUT ORANGE DEFAUT ORANGE Vérifiez l’alimentation principale, les fusibles externes, le sectionneur, COMP 1 OU 2 DEGIVRAGE BLANC DEBIT D’EAU...
  • Page 84 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION VOYANT ACTION LA MACHINE NE FONCTIONNE PAS ALIM PRINCIPALE ROUGE DEFAUT ORANGE DEFAUT ORANGE Vérifiez que les protections thermiques des compresseurs n’ont pas COMP 1 OU 2 disjonctées. Vérifiez le disjoncteur thermique sur le démarrage amorti (si installé).
  • Page 85 All manuals and user guides at all-guides.com FICHE TECHNIQUE POMPE A CHALEUR AIR A EAU POUR LES PISCINES ET BATTERIE CHAUDE (MODÈLE BM) MODELE PROPAC 30 PROPAC 45 PROPAC 70 PROPAC 90 PROPAC 140 UNITE CARACTERISTIQUES Air 20°C, humidité relative 65% Chauffage eau (à...
  • Page 86 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION POMPE A CHALEUR AIR A EAU POUR LES PISCINES ET BATTERIE CHAUDE (MODELE EM) MODELE PROPAC 30 PROPAC 45 PROPAC 70 PROPAC 90 PROPAC 140 CARACTERISTIQUES UNITE Air 20°C, humidité relative 65% Chauffage eau (à...
  • Page 87 All manuals and user guides at all-guides.com POMPE A CHALEUR AIR A EAU POUR LES PISCINES ET BATTERIE CHAUDE (BMY) MODELE PROPAC 30 PROPAC 45 PROPAC 70 PROPAC 90 PROPAC 140 CARACTERISTIQUES UNITE Air 20°C, humidité relative 65% Chauffage eau (à 26ºC) Puissance électrique 9.75 14.4...
  • Page 88 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION POMPES A CHALEUR AIR-EAU POUR LE CHAUFFAGE DE PISCINES (EMY) MODELE PROPAC 30 PROPAC 45 PROPAC 70 PROPAC 90 PROPAC 140 CARACTERISTIQUES UNITES Air 20°C, humidité relative 65% CHAUFFAGE Chauffage eau (à...
  • Page 89 All manuals and user guides at all-guides.com PLANS D’INSTALLATION SD566252 ISSUE 51...
  • Page 90 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION SD566252 ISSUE 51...
  • Page 91 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 92 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION SD566252 ISSUE 51...
  • Page 93 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 94 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION SD566252 ISSUE 51...
  • Page 95 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 96 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION SD566252 ISSUE 51...
  • Page 97 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 98 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION PROCEDURE D’ HIVERNISATION ATTENTION-DANGER: Disjonctez et isolez la machine avant de l’ouvrir! Comme la pompe à chaleur contient des équipements électriques et rotatifs, nous vous recommandons pour votre sécurité de faire appel à une personne compétente pour exécuter la procédure suivante.contient des équipements électriques et rotatifs, nous vous recommandons pour votre sécurité...
  • Page 99 All manuals and user guides at all-guides.com CONDITIONS DE GARANTIE Les exclusions suivantes s’appliquent à la Garantie accordée par Dantherm Ltd. Aucune réclamation ne sera acceptée dans les cas suivants: La pompe à chaleur n’a pas la capacité correcte pour l’application prévue.
  • Page 100 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION CIRCUIT FRIGORIFIQUE PROPAC M CIRCUIT FRIGORIFIQUE NOTE: LES PROPAC 90/140M UTILISENT 2 CIRCUITS FRIGORIFIQUES ISOLATION POINT D’INJECTION DU GAZ FILTRE DESHYDRATEUR (70/140) INDICATEUR DE DETENDEUR ELECTROVANNE LIQUIDE THERMOSTATIQUE FILTRE RESERVOIR DESHYDRATEUR PRESSOSTAT...
  • Page 101 All manuals and user guides at all-guides.com PROPAC MY CIRCUIT FRIGORIFIQUE NOTE: LES PROPAC 90/140MY UTILISENT 2 CIRCUITS FRIGORIFIQUES ISOLATION CAPILLAIRE VALVE ANTI-RETOUR POINT D’INJECTION DU GAZ SONDE DETENDEUR ELECTROVANNE DEGIVRAGE THERMOSTATIQUE RECHAUFFEUR, FILTRE BAC RECEPTEUR DESHYDRATEUR VALVE INDICATEUR ANTI-RETOUR DE LIQUIDE RESERVOIR EVAPORATEUR...
  • Page 102 All manuals and user guides at all-guides.com SYSTEME PRO-PAC MANUEL D’INSTALLATION FICHE D’INTERVENTION En application du règlement européen F-Gas, il est nécessaire de tester annuellement tout système hermétiquement scellé contenant 6 kg ou plus de gaz réfrigérant, et au-dessus de 30 kg de gaz réfrigérant le teste doit avoir lieu tous les 6 mois. L’entreprise ou la société...
  • Page 103 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 104 All manuals and user guides at all-guides.com danthermgroup.com Dantherm Ltd. Unit 12, Galliford Road Maldon CM9 4XD United Kingdom Calorex is part of the +44 (0)1621 856611 sales.uk@dantherm.com SD566252 ISSUE 51...
  • Page 105 All manuals and user guides at all-guides.com Pro-Pac system Pro-Pac 30/ 45/ 70/ 90/ 140M/MY Bombas de calor de aire/agua Manual de instalación para el propietario (SD566252 issue 51)
  • Page 106 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 107 All manuals and user guides at all-guides.com SALUD Y SEGURIDAD Puesto que el deshumidificador incluye equipos eléctricos y giratorios, en este tipo de máquinas SÓLO debe realizar trabajos personal cualificado. (Véase la Garantía). ÍNDICE BOMBAS DE CALOR AIRE/AGUA ..........4 INSTALACIÓN ................6 1.
  • Page 108 Estas máquinas, están completamente ensambladas y se recomiendan ser instaladas al exterior en un área bien ventilada. NOTA IMPORTANTE La compañía Dantherm Ltd. tiene el certificado ISO9001:2000 Todas las bombas de calor Calorex son aprobadas por la CE. SD566252 ISSUE 51...
  • Page 109 All manuals and user guides at all-guides.com EL CICLO DE LA BOMBA DE CALOR Las bombas de calor para piscinas CALOREX proporcionan un (similar al utilizado en un refrigerador convencional) y adicionalmente calor termodinámico por medio de un ciclo de compresión de vapor actúa como un activo colector solar.
  • Page 110 Asegúrese de que la bomba de calor es tal y como se había los planos de instalación). solicitado, es decir, el modelo, el suministro eléctrico y las Todas las bombas de calor Calorex son por diseño tan silen- opciones instaladas de fábrica. ciosas como prácticas. Sin embargo, debería prestarse una Inspeccione la máquina para comprobar que no está...
  • Page 111 All manuals and user guides at all-guides.com 2. FLUJO DE AIRE Hay que prestar una atención especial al flujo de aire, esto es, no obstruir la entrada o salida y asegurarse de que el aire de descarga no puede recircular hacia la entrada. (Consulte figuras1 y FIGURA 1 FIGURA 1 TIPICA INSTALACION EXTERIOR...
  • Page 112 1½” de profundidad puede ser colocada para permitir que la condensación se vacíe a través del desagüe. En tal caso es necesario que la bomba de calor Calorex este situada en una plataforma nivelada pues así puede salir con una caída adecuada de mínimo ie ½”...
  • Page 113 All manuals and user guides at all-guides.com IMPORTANTE 1. Todos los sistemas de depuración de la piscina y los sistemas de inyección química deberán situarse después de al salida del agua de la bomba de calor de la piscina a no ser que la instalación sea según la dosificación del filtro (consulte la figura 3).
  • Page 114 (ESTANDAR) ESQUEMA DE AGUA DE PISCINA ASEGURESE QUE LA BOMBA DE FILTRACION ELEGIDA FUNCIONA CORRECTAMENTE. FIG 3 PISCINA DOSIS QUIMICA- POSICION DESPUES DE LA BOMBA CALOREX CALENTADOR AUXILIAR (SI ESTA INSTALADO) CALOREX METODO MEDIDOR DE PRESION DE FLUJO-AJUSTE DEL FLUJO...
  • Page 115 All manuals and user guides at all-guides.com 5. CORROSIÓN ELECTROLÍTICA EN PISCINAS La corrosión electrolítica se da cuando metales diferentes que están en contacto unos con otros crean una diferencia de potencial entre ellos. A veces, separados por una sustancia conductora conocida como un electrolito, los metales diferentes crearán un pequeño voltaje (diferencia de potencial) que permite que los iones de un material pasen al otro.
  • Page 116 Inconsistencia en el suministro eléctrico Los siguientes limites de operación no deben ser excedidos para que las maquinas CALOREX puedan dar su máximo rendimiento así como el beneficio de la garantía. Voltaje Mínima Máxima...
  • Page 117 CODENSATORES DE TITANIO) “INTERLOCK”/BLOQUEO DE SEGURIDAD Fig. 5 INSTALACIÓN ELÉCTRICA PARA BOMBA DE CALOR CALOR CALOREX CON BOMBA DE AGUA MONOFÁSICA Todas las unidades tienen incorporado un “interlock” incorporado en el circuito de control, desplazado a dos terminales. Estos terminales están cortocircuitados por las pruebas de fábrica.
  • Page 118 DE ALIMENTACIÓN CODENSATORES DE PR0-PAC SYSTEM MANUAL DE INSTALACIÓN TITANIO) Fig. 5 INSTALACIÓN ELÉCTRICA PARA BOMBA DE CALOR CALOR CALOREX CON BOMBA DE AGUA MONOFÁSICA FUSIBLE AISLADOR CONMUTADO DENTRO 2M Y SELECCIONADA DE SUMINISTRO ACUERDO A LA HOJA DE DATOS BOMBA DE CALOR CALOREX TRIFÁSICA...
  • Page 119 All manuals and user guides at all-guides.com DIAGRAMMAS DE LOS CIRCUITOS ELÉCTRICOS PROPAC 30BM TRIFÁSICO (400V 3 N 50 Hz) INTERRUPTOR DEL CIRCUITO DE VENTILADOR CONTACTOR 6 (N/C) 6 (N/O) 4 (N/C) 4 (N/O) VENTILADOR 2 (N/C) 2 (N/O) INTERRUPTOR DEL CIRCUITO AJUSTES DEL TABLERO DE CONTROL DEL COMPRESOR CONTACTOR...
  • Page 120 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN PROPAC 45BM TRIFÁSICO (400V ~ 3 N 50 Hz) INTERRUPTOR DEL CIRCUITO DE VENTILDOR CONTACTOR 6 (N/C) 6 (N/O) AJUSTES DEL TABLERO DE CONTROL 4 (N/C) 4 (N/O) VENTILADOR 2 (N/C) 2 (N/O)
  • Page 121 All manuals and user guides at all-guides.com PROPAC 45EM TRIFÁSICO (220V ~ 3 60 Hz) INTERRUPTOR DEL CIRCUITO DE VENTILADOR CONTACTOR 6 (N/C) 6 NO 4 (N/C) 4 NO VENTILADOR 2 (N/C) 2 NO AJUSTES DEL TABLERO DE CONTROL INTERRUPTOR DEL CIRCUITO DEL COMPRESOR CONTROL COMPRESOR...
  • Page 122 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN PROPAC 70BM TRIFÁSICO (400V ~ 3 N 50Hz) INTERRUPTOR DEL CIRCUITO VENTILADOR CONTACTOR DE VENTILADOR 6 (N/C) 6 (N/O) 4 (N/C) 4 (N/O) AJUSTES DEL TABLERO DE CONTROL 2 (N/C) 2 (N/O) CONTROL...
  • Page 123 All manuals and user guides at all-guides.com PROPAC90BM TRIFÁSICO (400V ~ 3 N 50Hz) NEUTRO LÁMPARA DE SUMINISTRO AJUSTES DEL TABLERO DE CONTROL VENTILADOR 1 Y 2 CONTROL COMPRESOR 1 Y 2 2.5A 23.8A 1.1A 12 (N/C) N/O = NORMALEMENTE ABIERTO N/C = NORMALEMENTE CERRADO (N) 2 1 (L)
  • Page 124 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION PROPAC140BM TRIFÁSICO (400V ~ 3 N 50Hz) NEUTRO LÁMPARA DE SUMINISTRO AJUSTES DEL TABLERO DE CONTROL VENTILADOR 1 Y 2 CONTROL COMPRESOR 1 Y 2 2.5A...
  • Page 125 All manuals and user guides at all-guides.com PROPAC30 BMY TRIFÁSICO (400V ~ 3 N 50Hz) ATENUADOR INTERRUPTOR DEL CIRCUITO CONTACTOR DE ARRANQUE DEL COMPRESOR DE COMPRESOR SI SUMINISTRADO 6 (N/C) 6 (N/O) (W1) 4 (N/C) 4 (N/O) (V1) COMPRESOR 2 (N/C) 2 (N/O) (U1) 22 (N/C)
  • Page 126 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN PROPAC 45 BMY TRIFÁSICO (400V ~ 3 N 50Hz) INTERRUPTOR DEL CIRCUITO CONTACTOR DEL COMPRESOR DE COMPRESOR 6 (N/C) 6 (N/O) (W1) 4 (N/C) 4 (N/O) (V1) COMPRESOR 2 (N/C) 2 (N/O) (U1)
  • Page 127 All manuals and user guides at all-guides.com PROPAC 45 EMY TRIFÁSICO (220V ~ 3 60Hz) INTERRUPTOR DEL CIRCUITO DEL COMPRESOR SALTO/APAGADO = CONTACTOR DEL CONTACTOR APERTURA COMPRESOR 6 (N/C) 6 (N/O) (W1) 4 (N/C) 4 (N/O) (V1) COMPRESOR 2 (N/C) 2 (N/O) (U1) 22 (N/C)
  • Page 128 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN PROPAC 70 BMY TRIFÁSICO (400V ~ 3 N 50Hz) INTERRUPTOR DEL CIRCUITO DEL COMPRESOR SALTO/APAGADO = ATENUADOR DE ARRANQUE CONTACTOR CONTACTOR APERTURA SUMINISTRADO DEL COMPRESOR 6 (N/C) 6 (N/O) (W1) AJUSTES DEL TABLERO DE CONTROL 4 (N/C)
  • Page 129 All manuals and user guides at all-guides.com PROPAC 90 BMY TRIFÁSICO (400V ~ 3 N 50Hz) NEUTRO CORTACIRCUITOS RELÉ DE LÁMPARA DE DE CONTROL ROTATION DE FASE SUMINISTRO SALTO/APAGADO = CONTACTOR DE APERTURA (N/C) 2 (N/C) 4 (COM) 11 (N) 2 1 (L) (N/O) 14 (N/C) 6...
  • Page 130 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN PROPAC 140 BMY TRIFÁSICO (400V ~ 3 N 50Hz) NEUTRO CORTACIRCUITOS LÁMPARA DE RELÉ DE DE CONTROL ROTATIÓN DE FASE SUMINISTRO (N/C) 2 (COM) 11 (N/C) 4 (N/O) 14 (N) 2 1 (L) (N/C) 6...
  • Page 131 All manuals and user guides at all-guides.com PLAN DE MANTENIMIENTO REGULAR SD566252 ISSUE 51...
  • Page 132 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN MANDOS DE CONTROL Y LÁMPARAS DE INDICACIÓN TERMOSTATO El termostato digital ajustable de una etapa controla y mantiene el nivel de calor. Pulse y libere la tecla “P” para seleccionar la temperatura deseada. Para cambiar la temperatura a mayor o menor pulse y seleccione hacia arriba o hacia abajo los símbolos.
  • Page 133 All manuals and user guides at all-guides.com NO EN USO AUMENTAR TEMPERATURA DESEADA DISMINUIR TEMPERATURA DESEADA ACCESO A LA TEMPERATURA DESEADA INTERRUPTOR STANDBY ROJO VERDE AMBAR BLANCO AMBAR AMBAR PP90/140 M INDICADOR DE SUMINISTRO ELECTRICO. INDICADOR DE AVERIA GENERAL INDICADOR DE AVERIA DEL CIRCUITO 1 DEL REFRIGERADOR INDICADOR DE AVERIA DEL CIRCUITO 2 DEL REFRIGERADOR INDICADOR DE DESHIELO INDICADOR DE CAUDAL CORRECTO DE AGUA...
  • Page 134 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN FUNCIONAMIENTO DEFECTUOSO DE LA BOMBA DE CALOR Sólo un competente y autorizado técnico en refrigeración debería intentar reparar la unidad en lo relacionado con el circuito ADVERTENCIA: Aisle eléctricamente la máquina antes de manejar de refrigeracion de acuerdo con la norma EU 517/2014.
  • Page 135 All manuals and user guides at all-guides.com LUZ INDICADORA ACCIÓN LA UNIDAD NO ESTA FUNCIONANDO RED ELÉCTRICA ROJA APAGADO AVERIAS AMBAR APAGADO AVERIA REFRIG. AMBAR APAGADO Revise el suministro eléctrico- fusibles externos- aisladores- interruptores. 1 y/o 2 DESHIELO BLANCO APAGADO FLUJO/CAUDAL VERDE APAGADO...
  • Page 136 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN LUZ INDICADORA ACCIÓN LA UNIDAD NO ESTA FUNCIONANDO RED ELÉCTRICA ROJA ENCENDIDO AVERIA AMBAR ENCENDIDO AVERIA REFRIG. AMBAR APAGADO Revise los interruptores de calor de los ventiladores para que no saltado. Revise 1 y/o 2 el sistema de arranque suave (soft start) si esta incorporado).
  • Page 137 All manuals and user guides at all-guides.com FICHAS TÉCNICAS BOMBAS DE CALOR AIRE AGUA PARA PISCINAS Y USOS DE AGUA CALIENTE DOMESTICA UNIDADES 400V 3N~ 50HZ (BM) MODELO PROPAC30 PROPAC45 PROPAC70 PROPAC90 PROPAC140 UNIDADES CARACTERÍSTICAS Aire 20ºC, Humedad 65% CALENTAMIENTO Salida de agua (@ 26ºC) Consumo eléctrico 9.75...
  • Page 138 All manuals and user guides at all-guides.com FICHA TÉCNICA PROPAC EM PR0-PAC SYSTEM MANUAL DE INSTALACIÓN BOMBAS DE CALOR AIRE- AGUA PARA PISCINAS Y USOS DE AGUA CALIENTE DOMESTICA UNIDADES 220V 3~ 60HZ (EM) MODELO PROPAC 30 PROPAC 45 PROPAC 70 PROPAC 90 PROPAC 140 UNIDADES...
  • Page 139 All manuals and user guides at all-guides.com BOMBAS DE CALOR AIRE AGUA PARA PISCINAS Y USOS DE AGUA CALIENTE DOMÉSTICA UNIDADES 400V 3N~ 50HZ (BMY) MODELO:- PROPAC30 PROPAC45 PROPAC70 PROPAC90 PROPAC140 UNIDADES CARACTERÍSTICAS CALENTAMIENTO Aire 20°C, Humedad 65% Salida para agua (@ 26ºC) Consumo eléctrico 9.75 14.4...
  • Page 140 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN BOMBAS DE CALOR AIRE- AGUA PARA PISCINAS Y USOS DE AGUA CALIENTE DOMÉSTICA UNIDADES 220V 3~ 60HZ (EMY) MODELO PROPAC30 PROPAC45 PROPAC70 PROPAC90 PROPAC140 UNIDADES CARACTERÍSTICAS CALENTAMIENTO Aire 20°C, Humedad 65% Salida para agua (@ 26ºC) Consumo eléctrico 9.75...
  • Page 141 All manuals and user guides at all-guides.com PLANOS DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 142 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 143 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 144 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 145 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 146 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 147 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 148 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 149 All manuals and user guides at all-guides.com SD566252 ISSUE 51...
  • Page 150 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN SD566252 ISSUE 51...
  • Page 151 All manuals and user guides at all-guides.com PROCEDIMIENTO DE ADAPTACIÓN PARA EL INVIERNO ADVERTENCIA: ¡Aísle la máquina antes de abrirla! Puesto que la 5. Limpie el circuito de agua en la bomba de calor utilizando para bomba de calor incorpora equipo eléctrico y rotatorio, por su propia ello AGUA LIMPIA DEL GRIFO (NO AGUA DE LA PISCINA) por medio seguridad, se recomienda que el procedimiento lo realice personal de una manguera a la conexión de salida durante 10 minutos como...
  • Page 152 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN CONDICIONES DE LA GARANTÍA Las siguientes exclusiones son aplicables a la garantía dada por Dantherm Ltd. No se aceptará ninguna reclamación si: La bomba de calor tiene un tamaño incorrecto para la aplicación.
  • Page 153 All manuals and user guides at all-guides.com DIAGRAMMAS DE LOS CIRCUITOS DE REFRIGERACIÓN PROPAC M CIRCUITO REFRIGERANT NOTE QUE LOS MODELO Pro-Pac 90/140 -USAN DOS CIRCUITOS DE REFRIGERACIÓN NOTES DENOTA AISLACIÓN PROCESO PUERTO SECANTE DE REFRIGERANTE 70/140 INDICADOR VÁLVULA LÍQUIDO SOLENOIDE SECANTE DE RECIBIDOR...
  • Page 154 All manuals and user guides at all-guides.com PR0-PAC SYSTEM MANUAL DE INSTALACIÓN PROPAC M CIRCUITO REFRIGERANT NOTE QUE LOS MODELO Pro-Pac 90/140 -USAN DOS CIRCUITOS DE REFRIGERACIÓN NOTES DENOTA AISLACIÓN PROCESO PUERTO SECANTE DE REFRIGERANTE 70/140 INDICADOR VÁLVULA LÍQUIDO SOLENOIDE SECANTE DE RECIBIDOR REFRIGERANTE...
  • Page 155 El operador de la máquina es responsable de asegurarse que la prueba se lleve a cabo. Para las máquinas que requieran ésta prueba remitirse a la hoja de especificaciones. Un ejemplo de hoja de registro se muestra a continuación. Calorex es una compañía registrada en FGAS. Certificado número 1011570. Información general Nombre de la Máquina...
  • Page 156 All manuals and user guides at all-guides.com danthermgroup.com Dantherm Ltd. Unit 12, Galliford Road Maldon CM9 4XD United Kingdom Calorex is part of the +44 (0)1621 856611 sales.uk@dantherm.com SD566252 ISSUE 51...

Ce manuel est également adapté pour:

Pro-pac 45mPro-pac 70mPro-pac 90mPro-pac 140mPro-pac 30myPro-pac 45my ... Afficher tout