Installation
7) Attach supply lines to IPS inlet
connections (I). Using a wrench,
finish with one-half turn. DO NOT
overtighten.
1
1
Maintenance
1) Turn off water supply. Loosen and
remove the handle set screw (B),
handle (A), collar (C) and nut (D).
A
2
3
C
D
4
Troubleshooting Chart
Problem
Finish is spotting.
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to
cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Symmons Industries, Inc.
Copyright © 2019 Symmons Industries, Inc.
All manuals and user guides at all-guides.com
8) Attach supply lines to shut-off
valves and hand tighten. Using a
wrench, finish with one-half turn.
DO NOT overtighten.
1
I
2
2) Remove cartridge (F, G) and inspect
for debris. Replace cartridge if
necessary.
B
Elements in water supply may cause
water staining on finish.
31 Brooks Drive
Braintree, MA 02184
symmons.com
1
2
F
G
Cause
Phone: (800) 796-6667
gethelp@symmons.com
9) Turn on water supplies. Remove
aerator (H) and flush lines free of
debris. Check for leaks.
3) Install cartridge following steps
1 & 2 in reverse.
Solution
Clean finished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Fax: (800) 961-9621
ZV-3205 REV D