Converting Burners for Use with Natural
Gas
1. Remove control knobs, grates, caps, and burner
bowls.
2. Remove burners by removing burner screw with
Phillips screwdriver. Unplug burners from burner
wires.
3. Lift maintop off burner box to expose air shutters.
4. Turn orifice hoods counterclockwise (open)
1
approximately 1
/
to 2 turns.
2
5. Reassemble cooktop.
6. Adjust burner flame if necessary.
• See "Adjusting Surface Burner Flame" section.
Gas Supply Pressure
!
CAUTION
To avoid property damage, maximum gas supply
pressure must not exceed 14" WCP.
• Appliance and individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures
in excess of ½ psig (3.5kPa)(14" WCP).
• Appliance must be isolated from gas supply piping
system by closing manual shutoff valve during any
pressure testing of the gas supply piping system at
test pressures equal to or less than ½ psig (3.5kPa)
(14" WCP).
• Gas supply pressure for checking regulator setting
must be at least 1" WCP above manifold pressure
shown on rating label.
• Must use pressure regulator supplied with cooktop.
Gas Connection
Connect gas supply to regulator using hard pipe or a
flexible connector. Pressure regulator supplied with this
appliance has a ½ " NPT female connection.
• A manual shutoff, not supplied with cooktop, must be
installed in an accessible location outside of cooktop.
• Use joint compound that is resistant to action of
propane gas on all male pipe threads.
• Use supplied pressure regulator only.
• Do not overtighten gas fitting when attaching to
pressure regulator. Overtightening may crack regulator.
• Support pressure regulator with wrench when installing
gas fitting.
All manuals and user guides at all-guides.com
8
!
WARNING
To avoid property damage or personal injury, only use
a new flexible connector that is AGA/CGA design
certified.
• Do not use an old connector.
• Do not reuse a connector after moving appliance.
A—Regulator
B—Adaptor
C—Flexible Connector
D—Manual Shut Off Valve
Flexible Connection
F
A—Union
B—Manual Shut Off Valve
C—Reducing Elbow (3/4-inch to 1/2-inch)
D—3/4-inch Stub
E—1/2-inch Nipple
F—Regulator
Hardpipe Connection
A
B
C
D
A
B
C
E
D