1) Remove hanger bracket fastened to back of cooler by removing one (1) screw
2) Mount the hanger bracket as shown in Figure 1 (Pg. 2)
NOTE:
Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six
(6) 1/4 in. dia. mounting holes.
IMPORTANT:
5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper fit.
INSTALLATION OF COOLER
3) Hang the cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 1 (Pg. 2).
4) Remove the four (4) screws holding the lower front panel at the bottom of the cooler. Remove the front panel by pulling straight down and set aside.
5) Secure cooler frame to wall by installing (2) screws and washers (not supplied). (See Fig. 2, Pg. 6). Make sure the screws engage in a structural member.
6) Connect the supply water to the filter inlet tube.
7) Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut
and gasket to the trap and tighten securely.
IMPORTANT:
If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
BOTTLE FILLER INSTALLATION
8) Remove two (2) mounting screws with 5/32" Allen wrench holding bottle filler to wall mounting plate (See Fig.4, Pg. 6). Note do not discard mounting screws, they will be
needed to secure bottle filler to wall mounting plate.
9) Remove wall mounting plate from Bottle Filler (see Fig 4, Pg. 6). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the
six (6) mounting holes with a pencil (See Fig. 1, Pg. 2). Place tape over wiring harnes conection on top of cooler to prevent debris from falling into Connection (See Fig. 3, Pg.
6).
10) Remove wall mounting plate from wall.
11) Install wall mounting plate to wall using six (6) 7/16" obround mounting holes (mounting bolts not included) (See Fig.4, Pg. 6). Use appropriate fasteners for your wall type.
12) Install gasket on bottom of bottle filler tower with gasket support bracket & (2) screws (See Fig. 5, 6, Pg. 7).
13) Connect water line from cooler to 3/8" john guest fitting.
14) Place bottle filler on four (4) hooks on the mounting plate installed on wall. Make sure
15) Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that blue label can be read when
filter is installed. (Fig. 14, Pg. 10.)
16) Turn water supply on and inspect for leaks. In both cooler and bottle filler. Fix all leaks before continuing.
17) Once cooler and bottle filter has been inspected for leaks and any leaks found corrected, plug cooler into wall.
18) Reinstall two mounting screws from first step (See Fig. 4, Pg. 6). Caution, do not over tighten screws.
19) Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.
20) Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses might have air in line
which may cause a sputter. This will be eliminated once all air is purged from the line.
21) Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.
1) Remove lower cover on cooler by removing (4) screws (See Fig.10, Pg. 8).
2) Turn off water supply; dispense water to relieve pressure.
3) Turn used filter counterclockwise 1/4 turn to remove from filter head.
4) Remove cap from new filter and use to seal used filter.
5) Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig.14 on Pg. 10).
6) Turn on water supply and run a minimum of two gallons of water through the filter to purge air any fine carbon particles from filter. Also run water through bottle filler
Note:
Filter status light will automatically reset once new filter is installed.
1) Remove (2) mounting screws of bottle filler top cover using 5/32" Allen wrench.
2) Slide bottle filler up until the hooks of the plate disengage from body.
3) Tilt unit forward, the Programming Button is located on top of circuit board behind the graphics display.
ENLZS8WS_1F
HANGER BRACKET INSTALLATION
NOTE:
MUST
Mounting plate
be supported securely. Add fixture support carrier if wall will not provide adequate support.
Connect wiring harness to the top of cooler. (See Fig. 8, Pg. 8).
Instructions For Replacing Filters
Instructions To Access Programming Button
NOTE:
Do not disconnect wiring or plumbing.
round boss in gasket fits in hole of basin. (See Fig. 9, Pg. 8).
Page 3