UHF Wireless Microphone System | Installation and User Instructions |
5
Programming
Note
See the frequency overview on the last page of
this manual for the allowed frequency ranges in
your country.
The minimal frequency interval is 125 kHz.
When using multiple wireless microphone
systems close to each other, use a frequency
interval of 250 kHz or more to avoid interference.
5. 1
Receiver
Frequency selection
1 Turn the receiver ON by pressing the POWER
button (1).
2 Turn the handheld microphone ON by switching the
ON/OFF switch on the rear of the microphone to
the ON position. Or turn the belt-pack ON by
setting the switch to the ON position.
3 Press the SET button on the receiver for 2 seconds to
activate the menu. Once FREQ icon is blinking the
frequency can be selected by using the UP and
DOWN button.
4 Press the SET button again to store the selected
frequency.
figure 5. 1 : Frequency selection
Note
In case the receiver is locked, the settings can
not be changed. For unlock, see instructions on
Lock mode.
Bosch Security Systems | 2006-01 | 9922 141 50701ml
All manuals and user guides at all-guides.com
Frequency scanning
1 Press the SET button on the receiver for 2 seconds to
2 Press the SET button again and when the SCAN
3 Press the SET button again to store the selected
4 Adjust the AF signal by turning the output level
figure 5.2: Frequency scanning
Lock mode
1 Press the UP button for 3 seconds to activate LOCK
1
Note
The receiver automatically selects antenna A or
B, depending on receiving conditions (diversity).
activate the menu. Do not use the UP or DOWN
button.
icon is blinking press the UP or DOWN button to
start scanning. Scan UP or DOWN until the
frequency of the active microphone has been found.
frequency.
control knob (1) located on the front of the receiver.
1
ON or LOCK OFF.
Note
In case the LOCK mode is ON, the receiver
cannot be switched OFF.
en | 15